UV Sensor Installation:
1. First, unwrap the sensor carefully. Being very careful not to
drop or break the sensor eyepiece.
2. Wipe the sensor eyepiece with household alcohol to remove
dirt, oil and fingerprints.
3. Before inserting the UV sensor into the vessel check the o’ring
this is on the quartz eyepiece.
4. Insert the UV sensor assembly with gray gland nut.
Hand
tighten only!
5. Attach the other end of the UV sensors black amp electrical
connection to the lower right side of the meter. Insert the amp
into the twist lock connector. The connector will only fit into the
connector one way.
Hand Tighten Only!
UV Sensor Assembly
Quartz Dome
Eyepiece
UV Sensor Cell
Black Grommet
Gray Sensor Cord
Gray Quartz Nut with O'ring
Figure 1
O-ring
CAUTION:
NEVER LOOK DIRECTLY AT THE ULTRAVIOLET LIGHT WITH
THE NAKED EYE.
View through a piece of ordinary glass or optical
glasses.
ULTRAVIOLET LIGHT
may cause eye irritation if eye is not
properly protected. You should never have to look directly at the
ULTRAVIOLET LIGHT
when installing or trouble-shooting one of our
MWC-EM Water Sterilizers.