5.8.2 Pump heating circuits
Usually they are used for radiators, heating pools, etc. The following image describes the
components of a typical pump circuit which are required for flawless operation and
maintenance.
return line from heating circuit
heating circuit inlet
connection fitting
check valve
ball valves
integrated thermometers
circulating pump
connection fitting
We recommend using pump sets which make the installation faster and easier.
5.8.3 Mixing heating circuits
Typical usage is in projects where more heating circuits with different operating temperatures
need to be combined. Typical application is thus floor heating. The following image describes
the components of a typical mixing circuit which are required for flawless operation and
maintenance.
return line from heating circuit
heating circuit inlet
connection fitting
probe
check valve
ball valves
integrated thermometers
circulation pump
mixing valve
with servo 0-10V
connection fitting