54
DO NOT DIVE.
HEATER FLOW IS REDUCED (HFL)
There may not be enough water flow through the heater to carry the heat away from the heating
element. Heater start up will begin again after about 1 min. See “Flow Related Checks” below.
HEATER FLOW IS REDUCED (LF)*
There is not enough water flow through the heater to carry the heat away from the heating
element and the heater has been disabled. See “Flow Related Checks” below. After the problem
has been resolved, you must press any button to reset and begin heater start up.
HEATER MAY BE DRY (DR)*
Possible dry heater, or not enough water in the heater to start it. The spa is shut down for 15 min.
Press any button to reset the heater start-up. See “Flow Related Checks” below.
HEATER IS DRY*
There is not enough water in the heater to start it. The spa is shut down. After the problem has
been resolved, you must press any button to reset and restart heater start up. See “Flow Related
Checks” below.
HEATER IS TOO HOT (OHH)*
One of the water temp sensors has detected 118°f (47.8°C) in the heater and the spa is shut
down. You must press any button to reset when water is below 108°f (42.2°C). See “Flow Related
Checks” below.
A RESET MESSAGE MAY APPEAR WITH OTHER MESSAGES.
Some errors may require power to be removed and restored.
FLOW-RELATED CHECKS
Check filters for possible blockage. Try cleaning or replacing filters (especially if spa is equipped
with 24 hour circulation pump). Check for low water level, suction flow restrictions, closed valves,
trapped air, too many closed jets and pump prime.
On some systems even when spa is shut down, some equipment may occasionally turn on to
continue monitoring temperature or if freeze protection is needed.
* This message can be reset from the topside panel with any button press.
Spa Controls
Heater Related Messages
Содержание legacy whirlpool
Страница 1: ...OWNER S MANUAL...
Страница 2: ......
Страница 18: ...16 DO NOT DIVE SITE PREPARATION GENERAL GUIDELINES 102 DO NOT DIVE...
Страница 63: ......