3 Installation (see Fig. 1)
DANGER
Electric
shock risk
When installing, please ensure
electropump is disconnected
from
electrical supply.
WARNING
Protect the electropump and all
pipes from bad weather or
freezing conditions
DANGER
To prevent possible injuries to
people, avoid inserting hands
into the mouth of the DANGER
pump if this is connected to the
mains.
Use a suction pump (2) with a diameter equivalent
to that of the suction mouth of the electropump (1).
The suction line should be perfectly airtight. No
elbows and/or slopes should be present to prevent
the formation of air locks that could affect the
electropump efficiency.
A foot valve (3) with filter (4) should be fitted at
about half a metre below the fluid that has to be
pumped (HI) on one end
of the line.
It is advisable to install a check valve (6) directly on
the delivery line to prevent the electropump being
damaged by "water hammer".
A cut-off valve (7) should also be installed
downstream from the check valve, to facilitate
servicing operations. Piping should be fitted so that
vibrations, when existing, tension and weight do not
affect the pump. Piping should be routed along the
shortest and straighter track, avoiding an excessive
number of bends. Verify that the motor is properly
ventilated.
For permanent installations, it is advisable to fix the
electropump to the supporting base, connect the
system with a section of non flexible pipe and insert
a layer of rubber (or another anti-vibration material)
between the supporting base and the pump, in order
to reduce vibrations.
The site of installation must be stable and dry to
guarantee the stability of the pump.
Verify that the motor is properly ventilated.
ATTENTION!!!
Connection, suction and delivery pipes should
be connected with the utmost care. Make sure
that all connections fixed by means of screws
are sealed. Avoid applying excessive stress to
tighten the screws of connections or of
other components. Use a Teflon tape to
completely seal all joints.
The pump should be fitted in a stable position in
order to avoid falls and protect it from inundation.
Contact a specialised electrician.
4 Electrical connections
WARNING
Verify that the voltage and
frequency of the electropump
shown on the nameplate
correspond to those available on
the mains.
DANGER
Electric
shock risk
The installer must make sure that
the electric system is grounded
in accordance with the law in
force.
DANGER
Electric
shock risk
Make sure that the electric
system has a high-sensitivity
circuit
breaker Ä =30 mA (DIN VDE
0100T739).
5 Starting the unit (see Fig. 1)
WARNING
Use the electropump for the
applications listed on the
nameplate.
WARNING
Do not operate the electropump
without fluids.
WARNING
Do not run the electropump with
a completely closed delivery.
Instructions for a safe pump start
Avoid exposing the pump to humidity. Protect the
pump from rain, making sure that there are no
leaking fittings over the pump. Avoid using the pump
in wet or damp environments.
Make sure that the pump and the electric
connections are protected from possible inundation.
Before using the pump, always inspect it visually
(especially power cables and plugs). Do not use the
pump if it is damaged.
If the pump is damaged, have it inspected by the
specialised assistance service only.