background image

 

7

ELECTRICAL 
 

 
WARNING 
 

Before servicing electrical components in the case or the doors or door frames make sure all power to 
case is off.  Always use a qualified technician.

  

 

 

 
 
 
ELECTRICAL AND REFRIGERATION DATA 

 

Description 

SMB-330 SMB-430 

WMB-430 

SMB-580 

WMB-580 

SMB-870 

WMB-870 

FMB-430 FMB-580 FMB-870 

Condensing 
Unit 

Tecumseh 
AE3440-AA

 

Tecumseh 
AK9441-AA

 

Tecumseh 
AK9441-AA

 

Tecumseh 
AJ4492-AD

 

Tecumseh 
AE3440-AA

 

Tecumseh 
AK9441-AA

 

Tecumseh 
AK9441-AA

 

H.P. 

1/3 1/2 1/2 3/4 1/3 1/2 1/2 

Voltage 

115/60/1 

115/60/1 

115/60/1 

115/60/1 

115/60/1 

115/60/1 

115/60/1 

Total 

Amps 

11.6 15.0 15.0 22.5 11.6 22.5 15.0 

Refrigerant
Charge 

13 oz. 

21 oz. 

22 oz. 

23 oz. 

13 oz. 

23 oz. 

23 oz. 

Capillary 
Tube 

10 ft. 

.049 I.D. 

10 ft. 

.054 I.D. 

10 ft. 

.054 I.D. 

10 ft. 

.080 I.D. 

10 ft. 

.049 I.D. 

10 ft. 

.054 I.D. 

8 ft. 

.059 I.D. 

Temperature 
Control 

Cutler-Hammer 

9540N143 

Cutler-Hammer 

9540N143 

Cutler-Hammer 

9540N143 

Cutler-Hammer 

9540N143 

Ranco 

A30-1762 

Ranco 

A30-1762 

Ranco 

A30-1762 

Operating 
Pressure @ 85

 

Ambient 

H.P. 150# 

S.P. 18# 

H.P. 150# 

S.P. 18# 

H.P. 150# 

S.P. 18# 

H.P. 150# 

S.P. 18# 

H.P. 150# 

S.P. 18# 

H.P. 150# 

S.P. 18# 

H.P. 150# 

S.P. 18# 

Condensate 
Pan Heater 

300 Watts 

115 Volts 

300 Watts 

115 Volts 

300 Watts 

115 Volts 

300 Watts 

115 Volts 

300 Watts 

115 Volts 

300 Watts 

115 Volts 

300 Watts 

115 Volts 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

Содержание FMB-430

Страница 1: ...Installation Operations Manual Master Bilt Products 908 Highway 15 North New Albany MS 38652 Phone 800 684 8988 PN 251 90000 Rev 5 15 03 LPN...

Страница 2: ...2...

Страница 3: ...INSTALLATION INSTRUCTIONS 6 Inspection for ShippingDamage 6 INSTALLATION INSTRUCTIONS 6 General Instructions 6 Electrical and Refrigeration Data 7 Cleaning 8 STARTING PROCEDURE 8 FINAL CHECK LIST 8 SE...

Страница 4: ...adiant heat or air flow This will adversely affect the case and will result in poor performance If this case is to be located against a wall there should be at least 4 space between the wall and the b...

Страница 5: ...Important safety information is presented in this section and throughout this section and throughout the manual The following signal words are used in the warnings and safety messages DANGER Severe in...

Страница 6: ...so that older stock does not accumulate This is especially important for ice cream A First In First Out rotation practice will keep the products in good salable condition 4 Do not place product in th...

Страница 7: ...115 60 1 115 60 1 115 60 1 115 60 1 Total Amps 11 6 15 0 15 0 22 5 11 6 22 5 15 0 Refrigerant Charge 13 oz 21 oz 22 oz 23 oz 13 oz 23 oz 23 oz Capillary Tube 10 ft 049 I D 10 ft 054 I D 10 ft 054 I D...

Страница 8: ...OCEDURE Medium Temperature Refrigerators All SMB WMB models are equipped with a cord and plug cap When connected to power the condensing unit and evaporator fan s will start and the door heaters will...

Страница 9: ...ssures normal cabinet warm A Coil blocked with frost or ice see 4 B Refrigerant undercharged C Control set too warm 4 Coil blocked with frost or ice A Defective temperature control B Doors aren t seal...

Страница 10: ...0 Evaporator Coil 07 00135 07 00135 07 00135 07 00134 07 00135 07 00134 07 00134 Evaporator Fan Blade 15 01184 15 01184 15 01184 15 01184 15 01184 15 01184 15 01184 Evaporator Fan Guard 25 00205 25 00...

Страница 11: ...ND DISPOSAL OWNER RESPONSIBILITY If you sell or give away your Master Bilt cabinet you must make sure that all safety labels and the Installation Service Manual are included with it If you need replac...

Страница 12: ...12...

Страница 13: ...13...

Страница 14: ...14...

Отзывы: