INTRODUCTION 

 
Thank you for purchasing a Master-Bilt cabinet.  This manual contains important instructions for installing, 
using and servicing a Master-Bilt 

SMB/WMB

 case. A parts list is included in with this manual.  Read all these 

documents carefully before installing or servicing your equipment. 
 

 
STORE CONDITIONS

 

 
The Master-Bilt 

SMB/WMB

 cases are designed to operate in the controlled environment of an air conditioned 

store.  The store temperature should be at or below 75

°

F and a relative humidity of 55% or less.  At higher 

temperature or humidity conditions, the performance of these cases may be affected and the capacity 
diminished.  It is not uncommon in a newly constructed store for the temperature and humidity to be above 
design conditions.  These excessive conditions may produce sweating in the case until the store is operational 
and the ambient environment is more desirable.   
 
The Master-Bilt 

SMB/WMB

 should not be positioned where it is directly exposed to rays of sun or near a direct 

source of radiant heat or air flow.  This will adversely affect the case and will result in poor performance. 
 
If this case is to be located against a wall there should be at least 4” space between the wall and the back of 
the case.  This space will allow for the circulation of air behind the case which will prevent condensation on the 
exterior surfaces and allow the refrigeration system to discharge air properly. 
 
 
 

 

NOTICE 

 

Read this manual before installing your cabinet.  Keep the manual and refer to it before doing any 
service on the equipment.  Failure to do so could result in personal injury or damage to the cabinet. 

 

 

DANGER

 

 

Improper or faulty hook-up of electrical components of the refrigeration units can result in severe 
injury or death. 
 
All electrical wiring hook-ups must be done in accordance with all applicable local, regional or national 
standards.

 

 

 

NOTICE

 

 

Installation and service of the refrigeration and electrical components of the cabinet must be 
performed by a refrigeration mechanic and/or a licensed electrician. 

 
 
 
 
 
 
 
 
 
The portions of this manual covering refrigeration and electrical components contain technical instructions 
intended only for persons qualified to perform refrigeration and electrical work. 

 

 

 

Содержание FMB-430

Страница 1: ...Installation Operations Manual Master Bilt Products 908 Highway 15 North New Albany MS 38652 Phone 800 684 8988 PN 251 90000 Rev 5 15 03 LPN...

Страница 2: ...2...

Страница 3: ...INSTALLATION INSTRUCTIONS 6 Inspection for ShippingDamage 6 INSTALLATION INSTRUCTIONS 6 General Instructions 6 Electrical and Refrigeration Data 7 Cleaning 8 STARTING PROCEDURE 8 FINAL CHECK LIST 8 SE...

Страница 4: ...adiant heat or air flow This will adversely affect the case and will result in poor performance If this case is to be located against a wall there should be at least 4 space between the wall and the b...

Страница 5: ...Important safety information is presented in this section and throughout this section and throughout the manual The following signal words are used in the warnings and safety messages DANGER Severe in...

Страница 6: ...so that older stock does not accumulate This is especially important for ice cream A First In First Out rotation practice will keep the products in good salable condition 4 Do not place product in th...

Страница 7: ...115 60 1 115 60 1 115 60 1 115 60 1 Total Amps 11 6 15 0 15 0 22 5 11 6 22 5 15 0 Refrigerant Charge 13 oz 21 oz 22 oz 23 oz 13 oz 23 oz 23 oz Capillary Tube 10 ft 049 I D 10 ft 054 I D 10 ft 054 I D...

Страница 8: ...OCEDURE Medium Temperature Refrigerators All SMB WMB models are equipped with a cord and plug cap When connected to power the condensing unit and evaporator fan s will start and the door heaters will...

Страница 9: ...ssures normal cabinet warm A Coil blocked with frost or ice see 4 B Refrigerant undercharged C Control set too warm 4 Coil blocked with frost or ice A Defective temperature control B Doors aren t seal...

Страница 10: ...0 Evaporator Coil 07 00135 07 00135 07 00135 07 00134 07 00135 07 00134 07 00134 Evaporator Fan Blade 15 01184 15 01184 15 01184 15 01184 15 01184 15 01184 15 01184 Evaporator Fan Guard 25 00205 25 00...

Страница 11: ...ND DISPOSAL OWNER RESPONSIBILITY If you sell or give away your Master Bilt cabinet you must make sure that all safety labels and the Installation Service Manual are included with it If you need replac...

Страница 12: ...12...

Страница 13: ...13...

Страница 14: ...14...

Отзывы: