13
14
Duty Cycle
•
In current mode:
Signal input range: µA:
≥
60µA rms mA:
≥
6mA rms A:
≥
0.6A rms
(current input will increase as frequency increases)
Max. input current: 10A rms
•
In voltage mode:
Signal input range:
≥
0.6V AC rms
(voltage input will increase as frequency increases)
Input impedance: 10MΩ
Max. input voltage: 600V rms
•
Overload protection: Fuse (F600mA/600V)
Range
Resolution
Accuracy
0 1%~99
.
9
.
%
0.1%
±
3.0%
Temperature Measurement
Range
Resolution
Accuracy
-
20
°
C
~
1000
°
C
1
°
C
±(
2.0% of r2 digits)
-
4
°
F
~
1832
°
F
1
°
F
Frequency ( )
Hz
Range
Resolution
Accuracy
9.999Hz
0.001Hz
±(
1.5% of r5 digits)
99.99Hz
999.9Hz
0.01Hz
0.1Hz
•
Signal input range:
≥
2V
AC rms(voltage input will increase as
frequency increases)
• Max. input voltage: 600V rms
9.999kHz
0.001kHz
99.99KHZ
999.9KHZ
0.01kHZ
0.1KHZ
9.999MHZ
0.001MHZ
±(
2.0% of r4 digits)
Frequency (AC current)
Range
Resolution
Accuracy
99.99Hz
0.01Hz
±(
1.5% of r5 digits)
999.9Hz
>1kHz
0.1Hz
0.001kHz
Reference only
•
Signal input range: µA:
≥
60µA rms mA:
≥
6mA rms A:
≥
0.6A rms
(current input will increase as frequency increases)
•
Max. input current: 10A rms
•
≥
2V
•
Signal input range:
AC rms(voltage input will increase as
frequency increases)
Max. input voltage: 600V rms
Frequency ( )
%
Range
Resolution
Accuracy
1 – 99%
0.1%
±
2.0%
•
Max. input voltage: 600V rms
Frequency cont
.
(AC voltage)
(
)
Range
Resolution
Accuracy
99.99Hz
0.01Hz
±(
1.5% of r5 digits)
999.9Hz
>10kHz
0.1Hz
0.01kHz
Reference only
•
Signal input range:
≥
0.2V AC rms
(voltage input will increase as frequency increases)
•
Input impedance: 10MΩ
•
Max. input voltage: 600V rms
9
.
999
k
Hz
0.001kHz