background image

23

24

4.16 Judgment And Tracking Of Cable Line

4.16.1 Plug the attached detection line into the jack in 

            

front of

 

the meter and turn the rotary selector to

           

 the Tone range.

4.16.2

 

Connect the outgoing wire of the connecting line to

  

 

         

the

 

target cable pair or connect the red line to the

           

 target

 

cable and the black line to the ground.

4.16.3

 

Press the "

TEST

" key, and the" 

      

" symbol will 

            

flash

 

to transmit an audio signal. Bring the antenna

           

 of the

 

receiver close to the target cable and hold

           

 down the

 

Receive key to receive the audio signal 

            

transmitted, and

 

then you can judge the routing 

            

and continuity of the

 

cable. If there is any break

            

point on the cable, its position can

 

be judged.

1) There should be no AC or DC signal in the cable under

     

test.

2) If the audio signal is badly received, the volume switch

   

 of

 

the receiver can be adjusted.

Note:

4.17 Network Cable Integrity Test

4.17.1 Regular T568A/T568B cables can be judged for 
            open circuit, short circuit, miswiring, split pair, 
            reverse connection and shield integrity, and any 
            abnormality can be specified.
4.17.2 Insert both ends of the cable into the jacks in the 
            front and lower part of the meter.
4.17.3 Press the "

TEST

" key for testing. If the abnormality

            remains after the test, the “Abnormal” symbol will
            flash.
4.17.4 The front jack box can be separated to detect any 
            fixed cable as the remote terminal conveniently.

4.17.5 Insert a slotted screwdriver or any other flat object 
            into the notch and push up hard to remove the
            front cable interface.

Содержание MS8236

Страница 1: ...AL CLAMP METER MS8236 MS8236 DIGITAL MULTIMETER LAN Teter 2000 counts Autorange FUNC RANGE MAX HOLD TEST Net Cable NCV Ω V µA mA A OFF IEC61010 1 600V CAT III 10A µAmA VΩ COM MAX 600V MAX 10A 500V MAX 200mA 1000V Phone Tone ...

Страница 2: ... the test key 14 4 7 Preparation For Measurement 14 4 8 Measurement Of DC Voltage 15 4 9 Measurement Of AC Voltage 16 4 10 Diode Test 4 11 Circuit Continuity Test 4 12 Resistance Measurement 4 13 Measurement Of DC Current 17 17 18 19 20 23 24 4 15 Phone Line Mode Detection 21 4 16 Judgment And Tracking Of Cable Line 4 19 Operating Precautions Of Protective Cover 27 4 20 Automatic Power Off 28 5 Ma...

Страница 3: ...ge of above 60V DC or 30V AC 1 2 5 Do not take any voltage measurement if the value between the measuring terminal and the ground exceeds 1000V 1 2 6 Select the highest range if the value to be measured in the manual range is unknown 1 2 7 Do not connect the meter to any voltage source while the meter is in the current resistance diode or continuity test range 1 2 8 Disconnect the test probes from...

Страница 4: ...the replacement fuse must meet the specified voltage and current ratings of F 10A 500V and F200mA 1000V quick acting 1 4 5 Use wet cloth and mild detergent to clean the meter do not use abrasives or solvents 1 4 6 Turn to OFF switch off the power when is not in use 1 4 7 Remove the batteries to avoid damages to the meter if it will idle for a long time 1 4 8 Using this appliance in an environment ...

Страница 5: ...jack 14 Guard plate 2 2 Switches Buttons And Input Jacks HOLD key MAX key RANGE key For switching between auto and manual ranges FUNC key For switching among measuring functions Backlight key TEST key For measurement 10A jack Input jack for 10A current range mA A V jack and diode measurement COM jack Common terminal For reading holding μ Ω For maximum measurement For switching on off the backlight...

Страница 6: ...r 4 5 Cable pair 7 8 SHIELD Cable shield OPEN Open circuit SHORT Short circuit REVERSED Reverse connection MISWIRE Miswiring SPLIT PAIRS Split pair Audio signal 3 Specifications 3 1 General 3 1 1 Auto range and manual range options are available 3 1 2 Overload protection is available for all ranges 3 1 3 Display LCD 3 1 4 Maximum value display 1999 digits 3 1 5 Polarity indication automatic for ne...

Страница 7: ...1 DC Voltage Accuracy Resolution 0 1mV Range 200mV 0 5 of reading 5digits 2V 20V 200V 1000V 1mV 1V 0 1V 0 01V 0 8 of reading 5digits Max input voltage 1000V DC Note At the low voltage range unsteady readings will appear before the test probes contact the circuit This is normal because the meter is highly sensitive When the test probes contact the circuit the true reading will be displayed 3 2 2 AC...

Страница 8: ...0μA 20mA 200mA 2A 10A 0 1μA 1μA 0 01mA 0 1mA 0 001A 0 01A Overload protection μA mA range fuse 200mA 1000V quick acting 10A range fuse 10A 500V quick acting Max input current μA mA jack μA range 2000uA μA mA jack mA range 200mA 10A jack 10A 3 2 7 AC Current Accuracy Resolution Range 3 0 of reading 5 digits 1 5 of reading 5digits 200μA 2000μA 20mA 200mA 2A 10A 0 1μA 1μA 0 01mA 0 1mA 0 001A 0 01A Ov...

Страница 9: ...4 5 Backlight Source 1 If the environment is too dark for reading during measurement hold on to the key for more than 2 seconds to turn on the backlight source 2 Hold on to the key again for more than 2 seconds to turn off the backlight source 3 After the backlight source is turned on if the key is not held down for more than 2 seconds the backlight source will shut down automatically 15 seconds l...

Страница 10: ...ng high voltages Do not input any voltage of over AC750V rms which may damage the internal circuit though a higher voltage may be displayed 4 9 1 Plug the black probe into the COM jack and the red probe into the V jack 4 9 2 Set the range selector to the V range position 4 9 3 Press the RANGE key to select the auto or manual mode 4 9 4 Connect the test probes to the voltage source or load in paral...

Страница 11: ...e resistance of the circuit under test is less than 70Ω the buzzer in the meter will beep 4 11 6 Read the resistance of the circuit in the main display area of the LCD Note If the test probes are open or the resistance of the circuit under test is over 200Ω 0L will be displayed on the LCD 4 12 Resistance Measurement WARNING There is the risk of electric shock When measuring the impedance of a circ...

Страница 12: ... be set 3 means the maximum input current of the mA jack is 200mA and that of the 10A jack is 10A At the 10A jack excess current will blow the fuse 4 14 Measurement Of AC Current WARNING There is the risk of electric shock Turn off the power of the circuit under test and then connect the meter to the circuit in series for measurement 4 14 1 Plug the black probe into the COM jack When the current t...

Страница 13: ...f the detection result symbol flashes the mode of the phone line is as follows RED TIP flashing The TIP line is clamped by the red clip The RING line is clamped by the red clip RED RING flashing The phone line is in the ringing mode The phone line is in the standby mode The phone line is in the pick up mode flashing flashing flashing Note 1 If the RED TIP symbol flashes the standby and pick up mod...

Страница 14: ...cable its position can be judged 1 There should be no AC or DC signal in the cable under test 2 If the audio signal is badly received the volume switch of the receiver can be adjusted Note 4 17 Network Cable Integrity Test 4 17 1 Regular T568A T568B cables can be judged for open circuit short circuit miswiring split pair reverse connection and shield integrity and any abnormality can be specified ...

Страница 15: ...ower cords can be detected for the presence of AC voltage 4 18 2 Bring the upper part of the meter close to a conductor When a voltage is detected the meter will give a sound and provide visual indication Front detection area of the meter WARNING There is the risk of electric shock A voltage may still be present even if there is no indication Do not rely on the non contact voltage detection functi...

Страница 16: ... is used when the cable detection function is used 4 19 3 The figure below shows how the protective cover is used when the cable detection function is not used 4 20 Automatic Power Off 4 20 1 If the FUNC key or the range selector is not operated within 15 minutes during measurement the meter will be shut down and enter the sleeping mode to save electricity 4 20 2 To disable the automatic power off...

Страница 17: ...sure to use the designated fuse at rated voltage amperage and blow rate 5 2 1 Turn the range selector to OFF and remove the test leads from the input terminals 5 2 2 Remove the protective cover and unfasten the screws 5 2 3 Remove the rear case pry up one end of the fuse gently and then remove the fuse from the clip 5 2 4 After a new fuse is mounted replace the rear case and fasten the screws 5 3 ...

Страница 18: ...31 6 Accessories Test probes Protective cover Remote unit Operation manual 1 2 3 4 1 pair 1 1 1 5 6 1 1 Receiver Test connect line HYS006777 V2 ...

Отзывы: