Points of Attention during Operation
In order to ensure operation safety and operate with the optimal performance, please observe the following points of attention.
1. Initial checking
Before use for the first time, please check the tester for any abnormal function and make sure that no damage has occurred
during storage and shipment. Please contact the supplier in case any damage is found.
Table 2: Definition of the Precision Symbols
The smallest reading unit of the digital tester, i.e., the smallest effective number that can be shown
on the digital display.
Currently measured value and the displayed value on the tester.
This tester uses “±(% r digit)” to define the measurement tolerance, with the following descriptions
Digit
Reading or
displayed value
Warning
Before use, please make sure that the insulation of testing probes and cables is flawless and no conducting part is exposed
to the air. Otherwise, using the meter will cause electrical damage and injury. Please immediately contact the supplier for
replacement.
2. Storage
0
Ω
- 100 M
Ω
Range of humidity within which insulation
resistance test precision is guaranteed
Range of insulation resistance
Range of temperature within which insulation
resistance test precision is guaranteed
101 M
Ω –
20 G
Ω
21 G
Ω –
500 G
Ω
501 G
Ω –
5 T
Ω
<85% RH(no condensation)
<75% RH(no condensation)
<65% RH(no condensation)
<55% RH(no condensation)
23 ºC ± 5 ºC (73 ºF ± 9 ºF)
Please observe the following instructions to avoid electrical shocking and short-circuiting.
Before connecting or disconnecting a tester probe, please make sure that the probe is detached from the object being
measured and the power is turned off.
Please do not perform any measurement when opening the battery lid.
In case the cover of the socket is damaged, please do not use the tester.
Please do not take off the internal components. (Because there are high-voltage devices inside)
Please do not use the tester under environment with inflammable or explosive gas or with a lot of dust. (Otherwise
explosion might occur)
Please do not put the tester at a place where it is not stable. (In case the meter falls off, it might cause electrical
malfunctions and injuries.)
Warning
Direct sunlight
High temperature
Corrosive explosive gas
Spraying/splashing
Strong
electromagnetic
Dust
Mechanical
vibration
High voltage will be generated by this meter during measurements, and therefore please take insulation measures according
to industrial safety regulations in order to avoid electrical shock and injuries.
Before use, please remind relevant persons nearby to take protective measures.
In order to avoid malfunctions and accidents, please do not subject the meter to the following situations: