27
Table of configuration variables
CV
Description
D
A
Range Note:
1 Loco Address (Standard Short)
3
1... 127 If CV 29 bit 5 = 0
2 Starting Voltage
2
1... 255 CV 2 x (1/255 track voltage)
3 Acceleration Time
3
√
1... 255 CV 3 x 2ms x (1/255 track v.)
4 Braking Time
3
√
1... 255 CV 4 x 2ms x (1/255 track v.)
5 Top Speed
255
√
1... 255 CV 5 x (1/255 track voltage)
6 Mid Speed
64
1... 255 CV 6 x (1/255 track voltage)
5+6 Programming in Register Mode:
Register 6 = CV No.
Register 5 = Value
---
---
CV 5 and CV 6 are not effected
7 Software Version
---
---
read only
7
Decoder Reset Functions
(3 Ranges Available)
(see also Attachment 10)
55
basic setting
66
reset motor setting
77
reset lights and functions
8 Manufacturer ID
123
---
read only
9 Motor frequency
0
√
0... 3 0 = 16 kHz
1 = 2 kHz
2 = 250 Hz
3 = 60 Hz
13 Function Outputs in Analog Mode
(On if Value Set)
3
√
0... 63 A1 = 1 Add the values to the
A2 = 2 desired functions!
A3 = 4
A4 = 8
A5 = 16
A6 = 32
17 Long Loco Address (High Byte)
128
128...
10239
Only active
if CV29 bit 5 = 1
18 Long Loco Adress (Low Byte)
19 Consist adress
0
0... 99 Autom. consist address Lenz
®
29
Configuration Table NMRA
4
√
see Attachment 1
49
Configuration Table MASSOTH
2
√
see Attachment 2
50 Light: Dimming Value (PWM)
32
√
1... 32 32 = full track voltage