Installation
SELECTING A LOCATION
This barbeque is for outdoor use only and should be placed in
a well-ventilated area. Take care to ensure that the minimum
clearances guidelines are followed:
Minimum clearances:
From sides: 430mm; From back: 430mm
From above (vertical): 1000mm
Keep this barbeque away from any flammable materials! This
appliance shall only be used in an above ground open-air situation
with natural ventilation, without stagnant areas, where gas leakage
and products of combustion are rapidly dispersed by wind and
natural convection. This barbeque is not designed for marine use.
Any enclosure in which the appliance is used shall comply with one
of the following:
1.
An enclosure with walls on all sides, but at least one permanent
opening at ground level and no overhead cover.
2.
Within a partial enclosure that includes an overhead cover and
no more than two walls.
3.
Within a partial enclosure that includes an overhead cover and
more than two walls, the following shall apply:
a)
at least 25% of the total wall area is completely
open and unrestricted
b)
at least 30% of the remaining wall area is open
and unrestricted
4.
In the case of balconies, at least 20% of the total of the side,
back and front wall areas shall be and remain open and
unrestricted.
See following diagrams for further illustration:
OTHER PRECAUTIONS
Do not obstruct any of the ventilation openings in the barbeque
body. Should you need to change the gas cylinder, confirm that the
cylinder is off, and that there are no sources of ignition (cigarettes,
open flame, sparks, etc.) near before proceeding. Be sure to
inspect the gas hose and ensure it is free of any twisting or tension.
The hose should hang freely with no bends, folds, or kinks, which
could obstruct free flow of gas. Apart from the connection point, no
part of the hose should touch any hot barbeque parts. Inspect the
hose before use. If the hose is damaged, it must be replaced with
a hose suitable for use with LPG and meet the national standards
for the country of use. The length shall not exceed 1.5m. Should
minimum clearances not be adhered to severe flare up may be
experienced due to lack of airflow around the barbeque, thus
voiding manufacturer’s warranty.
GAS AND REGULATOR INFORMATION
This barbeque is designed for LP gas use only. Bottle sizes of 4.5kg
or greater are recommended for use with this barbeque. Suitable
LPG regulators must have an outlet pressure of 2.75 kPa. You must
have the proper regulator and bottle in order for the barbeque to
operate safely and efficiently. Please consult your local gas dealer
for the most suitable gas cylinders. Please note the regulator
supplied with this barbeque is of an approved type.
For more information on pipe sizing, please refer to AS5601/AG601
for details.
FIXING THE GAS REGULATOR TO THE CYLINDER
Confirm the barbeque control knob is in the off position.