Masport Inbuilt Gas Fires
- 9 -
19/11/04
BAY FRONT REMOVAL
1) Remove the top grille by lifting it upwards and
outwards to clear the retaining pins.
2) Release the bottom grille retaining screw by turning
it one quarter turn anti-clockwise. Remove the
bottom grille by moving it out at the bottom and
lifting it up off the retaining pins.
3) Remove the two window fastening screws, one at
each end of the top of the window.
4) The bay window can now be lifted clear by pulling
the top edge slightly outwards.
LOG & EMBER PLACEMENT
1) Once either the flush or bay windows are removed
as per the above instructions the embers can be
placed in the fire.
2) Inspect the logs before ember installation. If the
logs are broken, do not use the fire until they are
replaced. Broken logs can interfere with the pilot
operation, combustion, etc.
3) LOG IDENTIFICATION
790338 - Rear log, mounting centres - 340 mm
990339 - Left Centre log, mtg. centres - 115 mm
790356 - Left Front log, mtg. centres - 93 mm
790341 - Right Lower log, mtg. centres - 122 mm
790342 - Right Upper log, length - 245 mm
790343 - Centre log, length - 255 mm
Fit the first four logs on their mounting posts on
the gas burner in the following order:-
1. The Rear log
2. The Left Centre log
3. The Left Front log
4. The Right Lower log
Place the right Upper log on top of the hollow in
the right Lower log as illustrated, maintaining the
130 dimension shown to the rear of the firebox.
Place the Top log, positioned as shown with its
butt end sitting against the raised front lip of the
burner. Verify the correct distances to the right side
of the firebox.
4) Spread embers between and under the logs no
further than 50 mm back from front lip of burner and
also on the floor of the firebox at each side of the
burner. Do NOT block the ventilation slots in the
burner. Embers can be placed down the sides to hide
the black steelwork etc.
5) Re-install the flush or bay window. Do not operate
the appliance with the window removed.
GAS PRESSURE TEST
The unit is preset to give the correct gas input at the
specified injector pressures shown on the label. The
maximum injector pressure is:
Gas Type
Piccolo
EIS/ECS
Low
High
Low
High
Natural
Gas
0.30kPa
0.75kPa
0.35kPa
0.82kPa
Propane
0.90kPa
2.10kPa
1.00kPa
2.30kPa
The injector pressure is controlled by a regulator built
into the gas valve on EIS and ECS models. The
Piccolo has a pressure regulator separate from the
valve. In all cases, when adjusting the pressure, check
it at the outlet pressure test point on the valve. The
pressure check should be carried out with the unit
burning and the correct pressures are shown above.