Masport Geneva F39-LPG Скачать руководство пользователя страница 23

Masport F39 Room Sealed Freestanding Gas Fire

23

PARTS LIST

F39 MAIN ASSEMBLY

Part#:  Aust.    New  Zealand      Description

                           Part#: Aust.  New Zealand   Description

1)

560-920

Louver Assy - Gold (Set)

4)

730-038

Door Screen (Austraila only)

5)

*

Wire Holder Clip

8)

730-560

Relief Door Assembly (with gasket)

10) 730-034

Mounting Plate Gasket

11) 730-519/P

Fan Assembly (240 Volt)

910-169/P 556071 Fan Motor (240 Volt)

12) 910-714

560061 Power Cord (240 Volt)

15) 560-525

Pedestal Assembly

16) 730-039

Pedestal Door

17) 904-257

551893 Pedestal Door Magnet

18) 560-025

Pedestal Back

910-073

Spark Generator Battery Holder

19) 730-530

Side Panel Door Assy (Right Side)

20) 730-525

Side Panel Door Assy (Left Side)

21) 560-031

560242 Side Panel Door Hinge

23) 904-258

551891 Side Panel Door Magnet

24) 948-255

556074 Door Latch

25) *

Flex Pipe (3" ID)

26) *

Clamp for Flex Pipe

27) 910-233

560065 Fan Auto On/Off

Thermodisc

28) *

Mntg Bracket
-Thermodisc

29) *

Air Deflector

30) 730-044

Rear Panel

31) 630-021

Fan Access Panel

32) 730-028

Firebox Baffle

33) 630-520

False Top Assy

36) 936-194

Gasket - Starter
Collar/Air Passage

37) 936-197

Gasket - Flue Collar/
Starter Collar

38) 820-058

556077 Pedestal Base Cover

39) 730-036

Gasket - Air Passage

40) 730-042

Thermodisc Cover

41) 904-185

Cable Tie - High Temperature

42) 904-186

Cable Tie Mounting Button

910-033

Heat Resistant Sleeve

45) 750-031

Rear Control Panel

50) 910-140

560036 Fan Hi/Off/Low Switch

51) 910-246

560024 Burner On/Off Switch

918-089

Decal - Top Rear Control Panel

730-968

Conversion Kit to LPG

948-217

Logo Plate

918-082

Manual

*Not available as a replacement part.

Содержание Geneva F39-LPG

Страница 1: ...r FORYOURSAFETY Donotstoreorusegasolineorotherflamma ble vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorized installer servic...

Страница 2: ...ovide you with all the warmth and charm of a woodstove at the flick of a switch The models F39 NG and F39 LPGofthisserieshasbeenapprovedbyAGAforbothsafetyandefficiency Asitalsobearsourownmark it promi...

Страница 3: ...Installation Important Message 5 Specifications 5 Before You Start 5 General Safety Information 5 Installation Checklist 6 Clearances to Combustibles 6 Locating Your Masport Gas Fire 6 Combustion and...

Страница 4: ...om Sealed Freestand ing Gas Stove We have printed a copy of the contents here for your review The data plat is located on the inside of the drop down pedestal door NOTE Masport units are constantly be...

Страница 5: ...down to the floor 4 This appliance is Listed for bedroom instal lations when used with a Listed Millivolt Thermostat Some areas may have further requirements check local codes before installation 5 T...

Страница 6: ...led to inspect this appliance annually Make it a practice to have all of your gas appliances checked annually 13 Do not slam shut or strike the glass door 14 Under no circumstances should any solid fu...

Страница 7: ...ng installation The location of the termination cap must con form to the requirements in the Exterior Flue Terminal Locations diagram on page 8 Refer to the Masport Flue Kit in structions supplied wit...

Страница 8: ...nable window door or non mechanical air inlet or any other opening into a building with the exception of sub floor ventilation see also Note I Appliances up to 150 MJ h input 500 Appliances over 150 M...

Страница 9: ...Systems The shaded areas in the diagram below show all allowable combinations of vertical runs with horizontal terminations Maximum one 90O elbow two 45o elbows equal one 90o elbow LPG and NG Resident...

Страница 10: ...nnec tor and or copper tubing if allowed by local codes Since some municipalities have addi tional local codes it is always best to consult with your local authorities When using copper or flex connec...

Страница 11: ...AERATION ADJUSTMENT The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude F39 with 40mj F39 NG NG Full open F39 LPG LPG Full open F39 with 31mj F39 N...

Страница 12: ...ble 4 Remove and discard the 3 pressure reg ulator mounting screws A pressure regulator tower B and diaphragm C 5 Insure that the rubber gasket D is prop erly positioned and install the new HI LO pres...

Страница 13: ...ains Qty Part Description 1 904 390 Burner Orifice 52 LPG 1 918 034 Decal Converted to 30 000 Btu 1 918 033 Instruction Sheet Additional Piece pkg with unit 1 Log Bracket Restrictor 1 Shut off the gas...

Страница 14: ...t Pin D 02 46 B 02 56 A 02 65 7 Place the Left Top Log D 02 46 on the pin on Log B 02 56 and on top of the cutout on Log A 02 65 E 02 45 C 02 44 8 Place Front Right Log E 02 45 on the two pins as show...

Страница 15: ...adjust them by loosening the latch catch See diagram 3 Diagram 2 Diagram 3 5 Remove the blue plastic protective coating from the glass 6 Test the seal around the door by placing a piece of paper betw...

Страница 16: ...utorremovethegroundingprongfromthisplug INSTALLATION WIRING CAUTION Label all wires prior to disconnectionwhenservicingcon trols Wiring errors can cause im proper and dangerous operation This heater d...

Страница 17: ...to ON position 4 Turn ON the flame switch During the first few fires a white film may develop on the glass front as part of the curing process The glass should be cleaned or the film will bake on and...

Страница 18: ...ot touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbors phone Follow the gas supplier s in structions If you cannot reach your gas suppli...

Страница 19: ...e small proba bly yellow flames not coming into proper con tact with the rear of the burner or thermopile WARNING CHILDREN AND ADULTSSHOULDBEALERTEDTO THEHAZARDSOFHIGHSURFACE TEMPERATURE AND SHOULD ST...

Страница 20: ...r 7 Put gasket glue on the retainers but do not put glue on the screws Replace the door gasket the two ends butt tight together on the bottom edge of the door 8 Replace door on the stove and check the...

Страница 21: ...the following procedure a tighten top bottom outside corner nuts 2 b tighten inside nuts 3 c tighten top bottom inside corners 2 8 Tighten the 10 nuts on center glass retainer 9 Repeat step 7 for oth...

Страница 22: ...owing instructions Note Always close off the gas supply before removing the valve 1 Open front pedestal door You may want to put a soft cloth on the base of the unit so that when the pedestal door is...

Страница 23: ...1 560242 Side Panel Door Hinge 23 904 258 551891 Side Panel Door Magnet 24 948 255 556074 Door Latch 25 Flex Pipe 3 ID 26 Clamp for Flex Pipe 27 910 233 560065 Fan Auto On Off Thermodisc 28 Mntg Brack...

Страница 24: ...nerator Switch c w Wire 66 910 038 Pilot Assy S I T 3 Flame NG 910 039 Pilot Assy S I T 3 Flame LPG 67 PilotHolder 68 W840470 Pilot Assembly Gasket 71 730 528 Log Stand 904 641 556173 Pilot Orifice 50...

Страница 25: ...26 Black Mitred Door Complete 730 932 Gold Wrap Door Complete 730 928 Gold Panel Door Complete 101 650 920 560018 Door Gasket Kit 105 Ceramic Paper 106 940 323 P Side Glass 107 936 243 560087 Glass Ga...

Страница 26: ...____________________________________________________ ______________________________________________________ _______________________________________________________________ ____________________________...

Страница 27: ...nt This Express Warranty Does Not Cover 1 Defects malfunctions or failures caused by incorrect installation normal wear and tear misuse neglect acci dental damage or failure to follow the fuel selecti...

Страница 28: ...Printed in Canada Copyright 2004 FPI Fireplace Products International Ltd All rights reserved...

Отзывы: