Masotti TB6 Скачать руководство пользователя страница 4

TB61_1ENG

 

 

TB6 User’s manual      

4/8

 

General descripiton. 

TBS is a floor looper, completely true bypass, that manages up to six effects both in direct 
mode (by corresponding stomps) and via MIDI. Noise switch is absent tanks to our 
clickless technology based on a microprocessor that acts on the internal gold plated relais. 
Signal passes through them only, no semiconductor is present on the signal path. 
By the six stomps, any loop can be included or excluded at any time. Via MIDI, any 
combination of the six loops can be recalled by a simple Program change. The 
combination can be temporarily modified by the stomps and it can be restored simply 
sendind again the same Program Change.  
The same combination can be easily stored in different program changes (see next 
paragraphs).  Mechanical structure of TBS is roust for  heavy duty live applications. The 
loops status is clearly indicated by six red leds, while a multicolor led indicates the status 
of the device (normal or programming mode). 
Two or more TB6s can be easily connected in daisy chain.  
In the MGD products panorama, PW4 and MIDI STOMP are the ideal complements for 
TB6 to have a no-compromise and flexible pedal board. 

 
 
 

Commands and connectors. 

 

 

 

On the front panel, the six stomps are avalaible for the immediate access to loops. The 
corresponding leds indicate the loop status. Graphics allow the signal path visualization.  
 
 

 

On the right side we can find input jack, MIDI IN and MIDI THRU plugs. 

 
 

Содержание TB6

Страница 1: ...TB61_1ENG TB6 User s manual 1 8 Masotti Guitar Devices TB6 User s manual ...

Страница 2: ...ring new techniques and adopting the no compromise philosophy TB6 is a true bypass looper It manages up to six pedals in direct mode as well as via MIDI Noise switch is absent thanks to the microprocessor clickless technoloy developed by MGD and adopted in all our products IMPORTANT BEFORE SWITCH ON THE DEVICE PLEASE READ CAREFULLY THE IMPORTANT SAFETY NOTES AT PAG 8 ...

Страница 3: ...ral descripiton 4 Commands and connectors 4 Normal functioning 5 MIDI programming 5 Standard MIDI map 6 Connections 6 Power supply 6 Effects sequence 7 Inteconnecting cables and connectors 7 Warranty 7 Important safety notes 8 Technical specs 8 ...

Страница 4: ...n be restored simply sendind again the same Program Change The same combination can be easily stored in different program changes see next paragraphs Mechanical structure of TBS is roust for heavy duty live applications The loops status is clearly indicated by six red leds while a multicolor led indicates the status of the device normal or programming mode Two or more TB6s can be easily connected ...

Страница 5: ...s stored previously The recalled sequence can be modified by stomps and restored simply sending the PC again Default MIDI channel is 1 it can be modified in factory and it must be sepcified at the order moment Of course the effects connected to the loops must be powered and in active status MIDI patch reception is confirmed by a momentary yellow blinking of the status LED MIDI programming In order...

Страница 6: ...atch 3 loops 3 and 6 on patch 4 It is only a test map and you need to set your own map following the proper procedure as illustrated before Connections In the following picture you can find the standard connections for TB6 TYPICAL CONNECTIONS IN IN FX 1 OUT IN SEND1 RET1 FX 6 OUT IN RET6 SEND6 OUT 9V 500mA PWR SUPPLY MIDI IN MIDI THRU Power supply TB6 requires a 9V 500mA power supply A stabilized ...

Страница 7: ...nd preferences Inteconnecting cables and connectors True bypass systems if correctly projected and built introduce a negligible signal loss when they are in bypass TB6 is equipped with gold plated relais and connectors and it is wired with silver plated teflon isolated cables When in bypass its electrical eqivalent length corresponds to about 1m of good quality cable Nevertheless when loops are ac...

Страница 8: ...rvice refer to MGD or qualified and skilled personnel Never remove any screw Don t espose TB6 to rain water sparks excessive humidity chemical vapours heavy dust heat fonts strong vibrations Never introduce in the plugs objects different than corresponding connectors Always use CE FCC approved and good conditions power supply Before switch TB6 on check mains and ouptut voltages value on the power ...

Отзывы: