EXHAUST SYSTEM
Carbon monoxide.
Group generator use.
Carbon monoxide can cause severe nausea, fainting, or death.
Carbon monoxide is an odorless, colorless,tasteless, non irritating gas,able to, if
inhaled only also for brief time to provoke the death.
Be especially careful if operating the generator set when moored or anchored under
calm conditions as gases may accumulate.
If operating the generator set dockside, moor the ccraft so that the exhaust discharges
on the lee side (the side sheltered from the wind). Alway be aware of others-make sure
your exhaust is directed away from other boats and buildings.
HAZARDOUS VOLTAGE / ELECTRICAL SHOCK
Hazardous voltage. Moving motor.
Can cause severe injury or death.
Operate generator set only with all guards and electrical enclosures in place.
Grounding generator set. Hazardous voltage can cause severe injury or death.
Electroconduction is possible whnever electricity is present. Open main circuit
breakers of all power source before servicing equipment. Configure the installation
to electrically ground the generator set and alectrical circuits when in use.
Never contact electrical leads or appliances when standing in water or on wet ground,
as the chance of electroconduction increases under such conditions.
Disabling generator set.
Hazardous voltage can cause severe injury or death.
To disable the generating set from load, turn off the the automatic switch of the line
or disconnect the output cables from the commutation switch and block the final part
of cables. Hazardous voltage to load during an ispection cold cause severe damages
to people and to equipment. Do not use the emergency button instead the automatic
switch of the line.
Battery short circuit.
Explosion can cause severe injury or death. Short circuits can cause severe
damages to people and/or equipment. Disconnect the battery before doing installation
operations o generator set maintenances. Remove all jewels before doing
maintenance on the maintenance.
Remove negative (-) lead first when disconnecting battery. Reconnect negative (-)
lead last when reconnecting battery.
Never connect negative battery lead (-) to positive lead (+) of starting solenoid.