19
6.
Advanced system settings and optimization
Start using advanced settings only when you know what you are doing.
If you ran into troubles, connect beacon to PC via USB and use
Default button
. It uploads
“factory settings” to the board while keeping the device address untacked
6.1
Using oscilloscopes
6.1.1
Monitor ultrasonic signal from one beacon to another
Use Dashboard => View => Oscilloscope
to monitor ultrasonic signal from one
beacon to another. It is a very powerful tool, because it gives also information on the
background noise, level of the signal, echo. With this tool it is easy to set up the proper
ultrasonic threshold in the Dashboard.
Use this tool to set up the proper ultrasonic threshold in the Dashboard.
Echo;
External noise looks similarly.
Thus, choose the ultrasonic
threshold below this value, for
example, -500 to -2000
Type the reference beacon number.
And press Enter
Choose the beacon to test
Ultrasonic signal front