Marvel MPCP415 Скачать руководство пользователя страница 15

Cabinet

"Z" bracket

#8 x 

3

4

" black 

screws 

(3 places)

Figure 28

Step 7: Install the door

Carefully open the top and bottom hinges on the door being 

careful as there are many pinch points. Place the hinges 

over the 4 screws in the cabinet, 2 at the top and 2 at the 

bottom and slide the door into position. Tighten the 4 hinge 

screws with a phillips screwdriver. (See Figures 15 and 

15a). 

SECTION A-A 

SCALE 1 : 1

LOCK

NUT

BRASS EXTENSION

CAM

PHILLIPS SCREW

13/16 COUNTER

BORE 7/16 DEEP

1/2 HOLE

3/4 INCH

WOOD PANEL

SPRING WASHER

INNER

DOOR

Step 8: Secure the cabinet

Use the #8 x 

3

4

" black screws from the literature pack to 

secure the counter top to the cabinet top through the holes 

in the cabinet "Z" bracket.

INTEGRATED DOOR PANEL INSTALLATION

Figure 27

Step 6: Install lock cam

Attach the lock cam to the back of the lock assembly with 

the phillips head screw provided. Orient the lock cam verti-

cally when installing on the lock.

Cam stop

washer

Spring

washer

Cam

Set screw

Lock

Key

Retainer

nut

Screw

Brass 

extension

(2 lengths 

provided)

Step 5: Assemble lock parts

Two (2) lock extensions are provided with the lock. Use 

the longer extension for 

3

4

" thick integrated panels and the 

shorter one for 

5

8

" thick integrated panels. Assemble the 

lock extension, cam stop washer, spring washer, and set 

screw to the lock as shown in Figure 26 and 27.

Install this lock assembly into the lock hole in the integrated 

panel and secure with the retaining nut on the back side 

with a 15 mm socket and ratchet. Make sure the key slot in 

the front of the lock is vertical.

Figure 26

15

Содержание MPCP415

Страница 1: ...RATION T H E O R I G I N A L R E F R I G E R A T I O N E X P E R T S S I N C E 1 8 9 2 F O R M O D E L M P B V 4 1 5 OWNER S GUIDE MARVEL PROFESSIONAL UNDERCOUNTER REFRIGERATION THE OR I GI N AL RE F...

Страница 2: ...e and social media Bonus Third Year Warranty Free with Product Registration Your Marvel Professional product qualifies for a one year extension of the two year warranty coverage from your date of purc...

Страница 3: ...sal Integrated Panel Dimensions Integrated Panel Installation Installing The Water Supply Installing the Drain plumbing Maintenance Care and Cleaning Long Term Storage Winterization Operating Instruct...

Страница 4: ...em free installation and operation IMPORTANT SAFETY INSTRUCTIONS WARNING WARNING You can be killed or seriously injured if you do not follow these instructions WARNING State of California Proposition...

Страница 5: ...in ternal components in place The owners manual is shipped inside the product in a plastic bag along with the warranty registration card and other accessory items Important Keep your carton and packag...

Страница 6: ...d Fault Circuit Interrupters GFCI are prone to nui sance tripping which will cause the appliance to shut down GFCI s are generally not used on circuits with power equip ment that must run unattended f...

Страница 7: ...power outlet into the rear wall to gain the thickness of the power cord plug Not all recessed outlet boxes will work for this applica tion as they are too narrow but a recessed outlet box equivalent...

Страница 8: ...ht Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Readjust the front legs to level the unit after it is correctly positioned...

Страница 9: ...can be opened individually one at a time without interference Figure 10 However to ensure unobstructed door swing opening both doors at the same time 1 4 6 4 mm of space needs to be maintained betwee...

Страница 10: ...of door Figure 16 Figure 17 Figure 18 4 Remove caps from top of door Using a Philips Screwdriver install magnet actuator on opposite side Install caps into opposite side 5 Remove caps from screw hole...

Страница 11: ...d Door 15 38 1 cm wide appliance Right Hand Hinged Door 15 38 1 cm wide appliance Clearance for hinge at top and bottom Hinge side of door Top of door Left Hand Hinged Door 15 38 1 cm wide appliance L...

Страница 12: ...Integrated panel models are designed for use with built in installations only Use in freestanding instal lations could result in personal injury If you purchased an integrated panel model your unit is...

Страница 13: ...g at a corner of the door remove the magnetic door gasket from the interior side of the door see Figure 25 Set the gasket aside on a flat surface There are 10 holes in the gasket retainer extrusions 3...

Страница 14: ...oor and centered along the width of the door See Figure 24a Drill holes through the gasket extrusion using the 10 holes as pilot holes Use the drill size from the chart in Table A being careful not to...

Страница 15: ...e cabinet Z bracket INTEGRATED DOOR PANEL INSTALLATION Figure 27 Step 6 Install lock cam Attach the lock cam to the back of the lock assembly with the phillips head screw provided Orient the lock cam...

Страница 16: ...Cleaning section Showroom Mode Hold and for 5 seconds The F V PERO ZLOO DVK LVSOD ZLOO EH OLW DQG LQWHULRU OLJKW will function Unit will not cool Repeat command to return to normal operation Electron...

Страница 17: ...U the door is closed and standard bright white when the door is open See Control Operations sections for details and other options For more information about BrightShield visit www marvelrefrigeration...

Страница 18: ...to be pulled out from the installation for servicing or cleaning Connect the copper tubing to the top side of a cold water pipe to prevent the ice maker from plugging with sediment ease servicing the...

Страница 19: ...opriate drain and cut to length Optional Drain Pump An optional drain pump is available if you have purchased an ice machine without one and do not have access to a gravity drain Installation instruct...

Страница 20: ...tion instructions to determine the proper amount of cleaning solution to add based on evaporator plate Pour the cleaning the fresh water reservoir Splash shield brackets Pour cleaning solution slowly...

Страница 21: ...ent All models use LED lamps to illuminate the interior of the of the LED CAUTION Energy Saving Tips The following suggestions will minimize the cost of operating your ice machine appliance 1 sources...

Страница 22: ...ne must have all water drained and removed to prevent ice machine damage as well as possible water damage to the surrounding area in freezing conditions These damages are not covered under warranty Do...

Страница 23: ...to the reservoir and drain the remaining water left in the water line trap area To disconnect the water outlet line Push up on the white collar and pull the plastic water line from the bottom of the w...

Страница 24: ...the power cord to a wall outlet and turn the water leaks storage bin The drain pump should activate and discharge water Check for water leaks at all hose connections access for the air hose Apply air...

Страница 25: ...rt section In all correspondence regarding service be sure to give the service number serial number and proof of purchase Try to have information or description of nature of the problem how long the a...

Страница 26: ...hold refrigerator This subject is discussed on page Do you hear water being circulated in the ice machine This is a normal sound as water is added once every ice making cycle Is there a whoosing sound...

Страница 27: ...ributor tube restricted Check the water line to the ice machine to make sure there are no restrictions Troubleshooting the Drain Pump If the drain pump reservoir not the ice machine bin If the ice mac...

Страница 28: ...in question The part that caused the damage must be returned to Marvel in its entirety The part must be clearly labeled with the serial number of the unit it was removed from the date and the service...

Страница 29: ...y labor 2021 04 23 050H 1 I I I Year Warranty Claims Day Factory use Only Units must be registered prior to warranty submittal Customers may register at www marvelrefrigeration com A proof of purchase...

Страница 30: ...er and part description Some parts will require color or voltage information Marvel requires the return of original parts we will inform you when the parts order is taken This requirement will be note...

Страница 31: ...Of PROPERTY IN ACCORDANCE WITH FEDERAL OR LOCAL REGULATIONS FLAHHABLE REFRIGERANT USED R 600A Specifications Gloves and Eye Protection must be used R 600a is considered non toxic but is flammable when...

Страница 32: ...ended that a simple LPG gas detector is on site during service Ensure that all R 600a is removed from the system prior to brazing any part of the sealed system Only a clean dry leak free system should...

Страница 33: ...uate and charge with dry nitrogen for leak checks Repair leaks or replace system parts as required R 600A Specifications When re brazing the system must be purged with dry nitrogen and at least one ac...

Страница 34: ...microns prior to charging Weigh in the R 600a charge using a refrigerant scale run compressor an extra two minutes to clear the charging hoses Seal the Schrader Type access port a proper cap and seal...

Страница 35: ...um temperature temperature cool cool No Gas 0 PSIG to 25 Room Cool to hot temperature cool System Diagnosis Guide Condenser Capillary Evaporator Wattage Tube Very hot Warm Cold Normal Hot to warm Cool...

Страница 36: ...aces you touch are not hot or frozen Do not touch a bare circuit board unless you are wearing an anti static wrist strap that is grounded to an electrical ground or grounded water pipe Handle circuit...

Страница 37: ...39 HWC524 2A 40 HWC336 1A 41 HBD324 1A 42 HBD324 2A 43 HBD524 1A 44 HBD524 2A 45 HWD324 2A 46 HWD324 1A 47 HWD524 2A 48 HWD524 1A 49 HRF124 2A 50 HRF124 1A 51 HRI124 2A 52 HRI124 1A 53 Nugget R134A 54...

Страница 38: ...ht 2 Evap Fan Cond Fan 22 RE336 1A Compressor Top Left Valve Bot Right Valve Light 1 Light 2 Evap Fan Evap Fan 2 Cond Fan 23 RE515 1A Compressor Light 1 Light 2 Evap Fan Cond Fan 25 RE524 1A Compresso...

Страница 39: ...connection you should replace the thermistor and the thermistor harness Thermistor error information can be found in the Control Operations Service section This unit has two thermistors Thermistor one...

Страница 40: ...nce accident or improper use maintenance instal lation service repair acts of God fire flood or other natural disasters The product must be installed operated and maintained in accordance with the Mar...

Страница 41: ...e without notice Such revisions do not entitle the buyer to corresponding changes improvements additions replacements or compensation for previously purchased products www marvelrefrigeration com 1260...

Отзывы: