![Maruyama BL3200 Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/maruyama/bl3200/bl3200_owners-operators-manual_1733983014.webp)
— 13 —
OPERATION THE HANDHELD BLOWER
1.
Allow the engine to warm up for a few minutes.
2.
Control engine speed by the throttle trigger, or set the engine speed by the throttle setting lever.
*To adjust the throttle setting lever.
Press the throttle trigger, then adjust the throttle setting lever as you wish operation.
3.
Operate lower speed to blow leaves or debris ground.
4.
If the blow is not enough to blow, open the throttle gradually.
NOTE: Operate Handheld Blower at the lowest throttle setting to do the job.
REGULAR MAINTENANCE
Maintenance, replacement or repair of emission control devices and systems
may be performed by any repair establishment or individual; however, war-
ranty repairs must be performed by a dealer or service center authorized by
Maruyama, The use of parts that are not equivalent in performance and dura-
bility to authorized parts may impair the effectiveness of the emission control
system and may have a bearing on the outcome of a warranty claim.
AIR FILTER
Maintenance Interval
• The air filter should be cleaned and inspected each time the Handheld Blower is used, or more
often when working in extremely dusty conditions.
• Replace after every 100 hours of operation.
Air Filter Cleaning
1.
Move the choke lever to the closed(
)position.
2.
Loosen the knob and remove the air cleaner cover.
3.
Remove the foam element and filter screen from the air cleaner body.
WARNING
• Always wear eye protection, hearing protection, gloves, face filter mask and sturdy boots
with nonslip soles when operating the Handheld Blower.
WARNING
• Stop the engine before performing maintenance.