CMi210
CLAMP METER
Instruction
Manual
CMi210 instructions rev1.indd 2
16/06/2014 11:40:19
ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING
Thank you for buying one of our products. For safety and full
understanding of its benefi ts please read this manual before use.
Technical support is available from 01923 441717 and
[email protected].
CONTENTS
1
Safety Information
1
1.1 Meaning of Symbols and Markings
1
1.2 Precautions
2
2 Introduction
5
2.1 Inspection
5
2.2 Description
5
2.3 Accessories
6
3 Operation
7
3.1 General
7
3.2 Low Battery Indication
7
3.3 Description of Press Buttons
7
3.4 Description of LCD Symbols
8
3.5 Description
of
Terminals
9
3.6 Auto Power Off
9
3.7 Backlight
9
3.8 Auto/Manual
Ranging
9
3.9 Display
Hold
10
3.10 Max/Min
10
3.11 DC Current Zero
10
3.12 High Frequency Rejection
10
3.13 Live Circuit Detection
11
CMi210 instructions rev1.indd 3
16/06/2014 11:40:19
3.14 Lock Function
11
3.15 Use of the TL45 Test Leads
11
3.16 AC Current Measurements using Clamp
11
3.17 DC Current Measurements using Clamp
12
3.18 Inrush Current Measurements
13
3.19 AC Voltage Measurements
14
3.20 DC Voltage Measurements
14
3.21 AC & DC Current Measurements up to 400 mA
14
3.22 Resistance Measurements
15
3.23 Capacitance Measurements
15
3.24 Frequency and Duty Cycle Measurements
16
3.25 Temperature Measurements
16
3.26 Continuity Testing
17
3.27 Diode Testing
17
3.28 Insulation Resistance Measurements
18
4 Maintenance
19
4.1 Battery Replacement
19
4.2 Fuse
Replacement
19
4.3 Test Lead Replacement
20
4.4 Calibration
20
4.5 Cleaning
20
4.6 Repair & Service
21
4.7 Storage
Conditions
21
5 Warranty
22
Measurment Categories
23
Specifi cations
CMi210 instructions rev1.indd 6
16/06/2014 11:40:20
1
1 SAFETY INFORMATION:
REMEMBER: SAFETY IS NO ACCIDENT
These instructions contain both information and warnings that are necessary for
the safe operation and maintenance of this product. It is recommended that you
read the instructions carefully and ensure that the contents are fully understood.
Failure to understand and to comply with the warnings and instructions can result
in serious injury, damage or even death.
Particular attention should be paid to the Warnings, Precautions and Technical
Specifi cations.
Please keep these instructions for future reference. Updated instructions and
product information are available at: www.martindale-electric.co.uk
1.1 Meaning of Symbols and Markings
Caution - risk of danger & refer to instructions
Caution - risk of electric shock
Equipment protected by double or reinforced insulation (Class II)
Application around and removal from hazardous live conductors
is permitted.
>600V
Do not use in distribution systems with voltages higher than 680V.
Refers to the insulation resistance function.
CAT II
(Measurement Category II)
is applicable to test and measuring
equipment connected directly to utilization points (socket outlets and
similar points) of the low-voltage MAINS installation.
CAT III
(Measurement Category III)
is applicable to test and measuring
equipment connected to the distribution part of the building’s low-
voltage MAINS installation.
CAT IV (Measurement Category IV)
is applicable to test and measuring
equipment connected at the source of the building’s low-voltage
MAINS installation.
For further information on measurement categories refer to
page 23 or visit
www.martindale-electric.co.uk/measurement_categories.php
CMi210 instructions rev1.indd 1
16/06/2014 11:40:20