CMi210 

CLAMP METER

Instruction
Manual

CMi210 instructions rev1.indd   2

16/06/2014   11:40:19

 

 

 

ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

Thank you for buying one of our products. For safety and full 
understanding of its benefi ts please read this manual before use. 
Technical support is available from 01923 441717 and 
[email protected].

CONTENTS

1  

Safety Information   

1

1.1  Meaning of Symbols and Markings 

1.2 Precautions 

2

2 Introduction

 

5

2.1 Inspection 

5

2.2 Description 

5

2.3   Accessories 

6

 

3 Operation

 

7

3.1 General 

7

3.2  Low Battery Indication 

7

3.3  Description of Press Buttons 

7

3.4  Description of LCD Symbols 

8

3.5 Description 

of 

Terminals 

9

3.6  Auto Power Off 

9

3.7 Backlight 

9

3.8 Auto/Manual 

Ranging 

9

3.9 Display 

Hold 

10

3.10 Max/Min 

10

3.11  DC Current Zero 

10

3.12  High Frequency Rejection 

10

3.13  Live Circuit Detection 

11

CMi210 instructions rev1.indd   3

16/06/2014   11:40:19

3.14 Lock Function 

11

3.15  Use of the TL45 Test Leads 

11

3.16  AC Current Measurements using Clamp 

11

3.17  DC Current Measurements using Clamp 

12

3.18  Inrush Current Measurements 

13

3.19 AC Voltage Measurements 

14

3.20 DC Voltage Measurements 

14

3.21  AC & DC Current Measurements up to 400 mA 

14

3.22 Resistance Measurements 

15

3.23 Capacitance Measurements 

15

3.24  Frequency and Duty Cycle Measurements 

16

3.25 Temperature Measurements 

16

3.26 Continuity Testing 

17

3.27 Diode Testing 

17

3.28  Insulation Resistance Measurements 

18 

 

4 Maintenance 

19

4.1   Battery Replacement 

19

4.2 Fuse 

Replacement 

19

4.3  Test Lead Replacement 

20

4.4   Calibration 

20

4.5 Cleaning 

20

4.6  Repair & Service 

21

4.7 Storage 

Conditions 

21

 

5 Warranty 

22

 
 

Measurment Categories 

23

 

 Specifi cations

CMi210 instructions rev1.indd   6

16/06/2014   11:40:20

1

1 SAFETY INFORMATION: 

 

REMEMBER: SAFETY IS NO ACCIDENT

These instructions contain both information and warnings that are necessary for 

the safe operation and maintenance of this product. It is recommended that you 

read the instructions carefully and ensure that the contents are fully understood. 

Failure to understand and to comply with the warnings and instructions can result 

in serious injury, damage or even death.

Particular attention should be paid to the Warnings, Precautions and Technical 

Specifi cations.

Please keep these instructions for future reference. Updated instructions and 

product information are available at: www.martindale-electric.co.uk

1.1 Meaning of Symbols and Markings

 

Caution - risk of danger & refer to instructions

 

Caution - risk of electric shock

 

 Equipment protected by double or reinforced insulation (Class II)

  

 Application around and removal from hazardous live conductors 

is permitted.

>600V

 

 Do not use in distribution systems with voltages higher than 680V. 

Refers to the insulation resistance function.

CAT II  

 (Measurement Category II) 

is applicable to test and measuring 

equipment connected directly to utilization points (socket outlets and 

similar points) of the low-voltage MAINS installation. 

CAT III  

 (Measurement Category III) 

is applicable to test and measuring 

equipment connected to the distribution part of the building’s low-

voltage MAINS installation.

 CAT IV    (Measurement Category IV) 

is applicable to test and measuring 

equipment connected at the source of the building’s low-voltage 

MAINS installation.

  

 For further information on measurement categories refer to 

page 23 or visit 

www.martindale-electric.co.uk/measurement_categories.php

CMi210 instructions rev1.indd   1

16/06/2014   11:40:20

Содержание CMi210

Страница 1: ...ng 20 4 6 Repair Service 21 4 7 Storage Conditions 21 5 Warranty 22 Measurment Categories 23 Specifications 1 1 SAFETY INFORMATION REMEMBER SAFETY IS NO ACCIDENT These instructions contain both information and warnings that are necessary for the safe operation and maintenance of this product It is recommended that you read the instructions carefully and ensure that the contents are fully understood...

Страница 2: ...perating temperature and humidity range specified If the removable probe tip caps are not fitted to the probes of the test leads their measurement category becomes CAT II 1000V and they must not be used on CAT III or CAT IV installations to avoid the risk of shorting high energy circuits and arc flash When this unit is used in combination with test leads the measurement category of the combination is...

Страница 3: ...aximum indication is displayed MIN Minimum indication is displayed HOLD Display hold is activated APO Auto power off is activated INRUSH Inrush current measurement is selected 50V 100V 250V 500V 1000V Selected insulation resistance test voltage TEST Indicates insulation test active LOCK Insulation test voltage output is locked to on RANGE Manual ranging is selected SMOOTH Insulation resistance smo...

Страница 4: ...tion as required see section 3 12 Taking all necessary safety precautions press the clamp meter trigger to open the clamp jaws position the jaws around the CMi210 instructions rev1 indd 21 16 06 2014 11 40 22 12 conductor to be measured and release the trigger to close the jaws Position the clamp meter so the conductor is central within the clamp jaws Read the measured ac current from the display ...

Страница 5: ...ct polarity for electrolytic capacitors connect the test probes to the capacitor to be measured CMi210 instructions rev1 indd 29 16 06 2014 11 40 23 16 Read the measured capacitance from the display 3 24 Frequency and Duty Cycle Measurements Connect the black test lead to the COM terminal and the red test lead to the V Hz terminal Set the rotary switch to the Hz position Taking all necessary safet...

Страница 6: ...rnal circuits and remove the test leads and batteries before proceeding Replace only with the fuse specified The fuse is inside the battery compartment The battery compartment is underneath the unit and can be accessed by undoing the 2 screws and lifting off the cover CMi210 instructions rev1 indd 23 16 06 2014 11 40 22 20 Replace only with the original type 0 5 A 1000V 6 3x32mm fast blow ceramic f...

Страница 7: ...a court or other decision maker of competent jurisdiction such holding will not affect the validity or enforceability of any other provision or other part of that provision Nothing in this statement reduces your statutory rights CMi210 instructions rev1 indd 18 16 06 2014 11 40 22 23 CMi210 instructions rev1 indd 15 16 06 2014 11 40 21 SpeciÀcation CMi210 Insulation Clamp Meter All specified accura...

Страница 8: ... indd 7 16 06 2014 11 40 20 Duty Cycle Range Frequency range Resolution Pulse width Accuracy 5V logic 5 to 95 40Hz to 1kHz 0 1 10μs 2 0 10 10 to 90 1kHz to 10kHz 20 to 80 10kHz to 20kHz Overload protection 600V DC or AC rms Temperature Type K Thermocouple Range Resolution Accuracy 0 C to 400 C 1 C 1 0 2 50 C to 0 C 400 C to 1300 C 2 0 3 32 F to 750 F 1 F 1 0 4 58 F to 32 F 750 F to 2372 F 2 0 6 Ov...

Страница 9: ...ing case set of TL45 test leads probe set Type K thermocouple 5 x 1 5V AA batteries installed instructions SpeciÀcation CMi210 Insulation Clamp Meter CMi210 instructions rev1 indd 5 16 06 2014 11 40 20 ENVIRONMENTAL Temperature Humidity Operating 0 C to 50 C 70 R H Storage 20 C to 60 C 80 R H Altitude up to 2000m Pollution degree 2 indoor use SAFETY Conforms to BS EN 61010 1 BS EN 61010 2 032 CAT ...

Отзывы: