2.3 Accessories

The CMi210 comes with the following accessories:

‹

 Carrying case

‹

  Set of TL45 test leads

‹

  Type K thermocouple 

‹

  5 x 1.5V AA batteries (Installed)  

‹

 Instructions

Accessories not included:

‹

   TL180 insulation resistance test probe (incorporating test switch 

for ease of insulation tests)

CMi210 instructions rev1.indd   12

16/06/2014   11:40:21

7

3. OPERATION
3.1 General

If the magnitude of a parameter to be measured is uncertain, but 
known to be within the maximum safe limits of the electrical tester, 
manually set the range to maximum. For example, if measuring AC 
voltage and the voltage magnitude is unknown, set the range to 
750V, then if required, select the correct range for a satisfactory 
reading.

If the insulation clamp meter displays 

OL

 or 

-OL

 then the 

measurement limits of the range have been exceeded.

3.2 Low Battery Indication

The battery capacity is shown by the     symbols on the LCD.

If the   symbol is displayed followed by a 

bAtt 

display, the battery 

needs replacing as measurement accuracy can no longer be 
guaranteed (see section 4.1 Battery Replacement).

3.3 Description of Press Buttons

INRUSH

Selects inrush current measurement function

HFR

>2sec

Selects high frequency rejection -3db point

Turns backlight on/off

INSULATION

TEST

Press to perform insulation measurement

SEL

ZERO

Selects alternate functions for a rotary switch setting

Zero’s DC clamp current ranges

MAX

MIN

Selects max/min function

LOCK
HOLD

Locks the insulation test to continual measurement

Selects display hold on other measurement functions

RANGE

50V~1KV

Selects manual ranging

Selects test voltage for insulation resistance

CMi210 instructions rev1.indd   13

16/06/2014   11:40:21

8

3.4 Description of LCD Symbols

HFR1

High frequency reject > 1 kHz selected

HFR 2

High frequency reject > 10 kHz selected

MAX

Maximum indication is displayed

MIN

Minimum indication is displayed

HOLD

Display hold is activated

APO

Auto power off is activated

INRUSH

Inrush current measurement is selected

50V, 100V, 250V, 
500V, 1000V

Selected insulation resistance test voltage

TEST

Indicates insulation test active

LOCK 

 

Insulation test voltage output is locked to on

RANGE

Manual ranging is selected

SMOOTH

Insulation resistance smoothing is selected

Diode testing function is selected

Continuity function is selected

mV, V, μA, mA, 
A, μF, mF, 

:

, k

:

M

:

, G

:

, Hz, kHz, 

MHz, %, °C, °F

Units of measurement being displayed

Indicates battery level.

DC

Indicates DC measurement

AC

Indicates AC measurement

Indicates insulation resistance test voltage or external 
voltage is present at the  insulation terminals

Sub display

Main display

CMi210 instructions rev1.indd   16

16/06/2014   11:40:21

9

3.5 Description of Terminals

V

:

Hz

 

Input terminal for AC and DC voltage, resistance, capacitance 

continuity, diode test , frequency and duty cycle

COM

Common terminal

μA mA

Input terminal for AC & DC current measurements to 400 mA

K-TYPE

Input terminals for temperature probes

Insulation

Input terminal for negative insulation test lead

Input terminal for positive insulation test lead/probe

3.6 Auto Power Off

If the clamp meter is inactive for a period of 30 minutes it will 
automatically power off.

If any button is pressed after the clamp meter has automatically 
powered off, the clamp meter will turn back on.

To disable the auto power off function hold the 

MAX

MIN

 button at the 

same time as turning the rotary switch from 

OFF

 to any position. The 

APO 

symbol will no longer be displayed on the LCD.

3.7 Backlight

To switch on the backlight press the 

HFR

>2sec

button for > 2 seconds. 

Press again for > 2 seconds to turn the backlight off.

3.8 Auto/Manual Ranging

To select manual ranging, press the 

RANGE

50V~1KV

 button. The 

RANGE

 

symbol will be displayed on the LCD to signify manual ranging is 
selected.

To manually select a range when in manual mode press the 

RANGE

50V~1KV

 

button until the required range is selected.

CMi210 instructions rev1.indd   17

16/06/2014   11:40:22

Содержание CMi210

Страница 1: ...ng 20 4 6 Repair Service 21 4 7 Storage Conditions 21 5 Warranty 22 Measurment Categories 23 Specifications 1 1 SAFETY INFORMATION REMEMBER SAFETY IS NO ACCIDENT These instructions contain both information and warnings that are necessary for the safe operation and maintenance of this product It is recommended that you read the instructions carefully and ensure that the contents are fully understood...

Страница 2: ...perating temperature and humidity range specified If the removable probe tip caps are not fitted to the probes of the test leads their measurement category becomes CAT II 1000V and they must not be used on CAT III or CAT IV installations to avoid the risk of shorting high energy circuits and arc flash When this unit is used in combination with test leads the measurement category of the combination is...

Страница 3: ...aximum indication is displayed MIN Minimum indication is displayed HOLD Display hold is activated APO Auto power off is activated INRUSH Inrush current measurement is selected 50V 100V 250V 500V 1000V Selected insulation resistance test voltage TEST Indicates insulation test active LOCK Insulation test voltage output is locked to on RANGE Manual ranging is selected SMOOTH Insulation resistance smo...

Страница 4: ...tion as required see section 3 12 Taking all necessary safety precautions press the clamp meter trigger to open the clamp jaws position the jaws around the CMi210 instructions rev1 indd 21 16 06 2014 11 40 22 12 conductor to be measured and release the trigger to close the jaws Position the clamp meter so the conductor is central within the clamp jaws Read the measured ac current from the display ...

Страница 5: ...ct polarity for electrolytic capacitors connect the test probes to the capacitor to be measured CMi210 instructions rev1 indd 29 16 06 2014 11 40 23 16 Read the measured capacitance from the display 3 24 Frequency and Duty Cycle Measurements Connect the black test lead to the COM terminal and the red test lead to the V Hz terminal Set the rotary switch to the Hz position Taking all necessary safet...

Страница 6: ...rnal circuits and remove the test leads and batteries before proceeding Replace only with the fuse specified The fuse is inside the battery compartment The battery compartment is underneath the unit and can be accessed by undoing the 2 screws and lifting off the cover CMi210 instructions rev1 indd 23 16 06 2014 11 40 22 20 Replace only with the original type 0 5 A 1000V 6 3x32mm fast blow ceramic f...

Страница 7: ...a court or other decision maker of competent jurisdiction such holding will not affect the validity or enforceability of any other provision or other part of that provision Nothing in this statement reduces your statutory rights CMi210 instructions rev1 indd 18 16 06 2014 11 40 22 23 CMi210 instructions rev1 indd 15 16 06 2014 11 40 21 SpeciÀcation CMi210 Insulation Clamp Meter All specified accura...

Страница 8: ... indd 7 16 06 2014 11 40 20 Duty Cycle Range Frequency range Resolution Pulse width Accuracy 5V logic 5 to 95 40Hz to 1kHz 0 1 10μs 2 0 10 10 to 90 1kHz to 10kHz 20 to 80 10kHz to 20kHz Overload protection 600V DC or AC rms Temperature Type K Thermocouple Range Resolution Accuracy 0 C to 400 C 1 C 1 0 2 50 C to 0 C 400 C to 1300 C 2 0 3 32 F to 750 F 1 F 1 0 4 58 F to 32 F 750 F to 2372 F 2 0 6 Ov...

Страница 9: ...ing case set of TL45 test leads probe set Type K thermocouple 5 x 1 5V AA batteries installed instructions SpeciÀcation CMi210 Insulation Clamp Meter CMi210 instructions rev1 indd 5 16 06 2014 11 40 20 ENVIRONMENTAL Temperature Humidity Operating 0 C to 50 C 70 R H Storage 20 C to 60 C 80 R H Altitude up to 2000m Pollution degree 2 indoor use SAFETY Conforms to BS EN 61010 1 BS EN 61010 2 032 CAT ...

Отзывы: