![Martin Stage Cyclo Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/martin/stage-cyclo/stage-cyclo_user-manual_1732677027.webp)
Troubleshooting
27
Troubleshooting
Problem
Probable cause(s)
Remedy
No response from fixture when
power is applied.
No power to fixture.
Check power connections.
Ground fault protection circuit
breaker (RCD) has tripped.
Reset RCD. If problem
persists, have an electrician
replace the RCD or reduce the
number of fixtures powered
via one RCD.
Fixture does not respond
correctly to DMX control.
Controller not connected.
Check DMX data link. Inspect
connections and test cables.
Repair or replace as
necessary.
Incorrect DMX addressing.
Check address setting on
fixture and controller.
Data link not terminated.
Insert DMX termination plug in
unused socket of last fixture
on data link.
Fixture on link set as master.
Check that all fixtures are set
as slaves (DIP switch pin 9
ON).
Defective fixture.
Bypass fixtures one at a time
until normal operation is
regained.
Fixtures do not behave
correctly in master/slave mode
Two fixtures operating as
masters.
Check that only one fixture is
set as master.
Defective fixture.
Bypass fixtures one at a time
until normal operation is
regained.
Poor quality light output and/or
color rendering.
Tube or tubes not burnt in.
Run fixture for at least 100
hours to burn in tubes.
Tube defective.
Disconnect fixture and replace
tube.