© Martin Engineering GmbH
27
M3682UK-09/17
Installation
5.2.5
Aligning the mainframe parallel to the conveyor belt
Tab. 9: Top view of aligning the secondary cleaner in parallel to the
conveyor belt
1. Measure the clearance on both sides between the mainframe
and the head pulley or counter-pressure roller.
Fig. 21:
Item
Description
1
Top view of the blades
2
Driving drum
3
Driving drum axis
4
Chute wall
NOTE
The measurements must be the same on both sides.
4
1
3
2