      Basic Service and Maintenance                                                                             

2. Move jumper PL121 to pins 1 and 2 (hard boot setting) as

shown. See also the circuit board layout diagram on page 30.

3. Apply power to the RoboScan Pro 918 and proceed with the

upload as described in the uploader manual.

4. After the upload, disconnect the fixture from AC power, move

the jumper back to the normal setting, and replace the circuit board section.

C

U S T O M

 

G O B O S

For best focus, custom gobos for the RoboScan Pro 918 should be made with the artwork reversed on the coated side.
See page 31 for gobo specifications.

Chrome-coated glass gobos are not recommended: they absorb more heat than enhanced aluminum gobos and are
likely to break or oxidize. The lifetime of chrome gobos is extremely short in the Pro 918; but, if used, their lifetime
can be extended somewhat by inserting the gobos with the coated side towards the lamp.

C

H A N G I N G

 

R O T A T I N G

 

G O B O S

W i t h o u t   t o o l s

1. Remove the effects section cover.

2. Turn the gobo wheel so you can reach the desired gobo. Turn the color wheel until the open position is over

the gobo.

3. Push the gobo and retaining spring out of the back of the holder. Avoid letting the spring and gobo fall into

the effects compartment.

4. Insert the new gobo. See below for proper orientation.

5. Insert the retaining spring with the bend facing out, away from the gobo. Working through the open position

in the color wheel, push the gobo and spring all the way down into the gobo holder. 

W i t h   n e e d l e n o s e   p l i e r s

1. Remove the effects section cover as described above.

2. Turn the gobo wheel until the easiest access to the desired gobo position is obtained. Turn the color wheel

until the open position is over the gobo position.

3. Turn the gobo holder until you can see the tab on the holder retaining spring. 

4. Grip the tab on the retaining spring with a pair of small (needlenose) pliers. Place your index finger over the

spring to prevent it from falling into the fixture. Open the spring and remove it from the gobo holder.

5. Remove the gobo holder from the bearing by pulling it forwards towards the mirror. 

6. Push the gobo and gobo retaining spring out of the holder. 

7. Insert the new gobo. See below for proper gobo orientation.

8. Insert the retaining spring with the bend facing out, away from the gobo. Push the gobo and spring all the

way down into the gobo holder. 

9. Replace the gobo holder in the bearing. Do not force the holder into the bearing: it will go in easily if it is

installed straight. 

10. Grip the retaining ring by the tab with the pliers. Place your thumb on the back of the gobo holder to press it

all the way down in the bearing and use your index finger to hold the other end of the spring on the holder.
Open the spring and place it in the groove. 

PIN 1 

È

PL121

PL121

PIN 1 

È

 hard boot setting

normal setting

Содержание RoboScan Pro 918

Страница 1: ...RoboScan Pro 918 user manual...

Страница 2: ...Professional A S Denmark All rights reserved No part of this manual may be reproduced in any form or by any means without permission in writing from Martin Professional A S Denmark Printed in Denmark...

Страница 3: ...section 4 Operation Martin RS 485 control 14 DMX 512 control 14 Stand alone control 14 Controllable effects 15 section 5 Basic Service and Maintenance Accessing parts 17 Changing voltage and frequency...

Страница 4: ...p becomes defective or worn out Allow the fixture to cool for 15 minutes before replacing the lamp Keep all combustible materials for example fabric wood paper at least 0 5 meters 20 inches away from...

Страница 5: ...tory pre cise alignment may be necessary due to slight variations between lamps The procedure is described on page 21 W A R N I N G Disconnect the fixture from AC power before proceeding Always wear s...

Страница 6: ...Do not connect the Pro 918 to a dimmer system doing so will damage the fixture I N S T A L L A T I O N U sing the mo unting bracket as a floor st and W A R N I N G When standing the fixture with the...

Страница 7: ...nt 7 Tighten the rigging clamp s securely to the structure 8 Fine tune the position and the fully tighten the slide clamps and swivel locks C O N N E C T I N G T H E S E R I A L L I N K The default pi...

Страница 8: ...teristic impedance shielded cable with 1 or more twisted pairs For runs up to 500 meters 1640 ft use 22 AWG cable Use an amplifier if the serial link exceeds 500 meters Never use a Y connector to spli...

Страница 9: ...key press The DMX or Martin address depending on the protocol setting and any error messages are displayed when the RoboScan Pro 918 is turned on To enter the menu press MENU Use the and keys to move...

Страница 10: ...nsity DMX lamp off SPEC dLOF ON Enable DMX lamp off command OFF Disable DMX lamp off command DMX reset SPEC dRES ON Enable DMX reset command OFF Disable DMX reset command Automatic lamp on SPEC ALON O...

Страница 11: ...RLST The resettable counters may be used to track overall usage and lamp life To reset to zero display the readout and then press for 5 seconds D MX va l ue r e adou ts dMXL Read the DMX start code S...

Страница 12: ...2 preprogrammed demonstrations Demo 1 shows each effect individually and in combination with others Pan and tilt are static Demo 2 pans and tilts within a defined area and shows various effect combin...

Страница 13: ...om configurations SPEC dFSE CUS1 CUS2 CUS3 Save and load 3 sets of custom configurations To save a custom configuration adjust the settings as desired go to CUS1 CUS2 or CUS3 and press ENTER when SAV...

Страница 14: ...it is the best choice with controllers that calculate intermediate positions that are close to the line of travel MOd2 uses the real value of the DMX delta to calculate speed and is better if the inte...

Страница 15: ...72 Movement may be optimized for speed by setting the pan tilt speed PTSP per sonality to FAST or for smoothness by setting it to SLOW The setting may be overridden on the speed channel in vector mod...

Страница 16: ...selected while the gobo rotates between positions To change the gobos see Changing rotating gobos on page 20 R ot a t i n g p ri s m va r ia bl e f ro st The 3 facet prism can rotate in both direction...

Страница 17: ...E ffe c ts s ec ti o n 1 Disconnect the fixture from AC power 2 Turn the locking pins A on the back plate 1 2 turn 3 Pull the cover back and off 4 To replace the cover position the rails on the cover...

Страница 18: ...the table above The colors refer to the wires that enter the connection block at the bottom The figure to right shows the transformer connection block as seen from the top On the transformer F move th...

Страница 19: ...e used 1 Access the printed circuit board as described above 2 Position the jumpers on PL 233 and PL 234 for the desired XLR pin out as shown U P D A T I N G S O F T W A R E The latest software for th...

Страница 20: ...with the bend facing out away from the gobo Working through the open position in the color wheel push the gobo and spring all the way down into the gobo holder W i t h n ee d l en o s e p l i e rs 1 R...

Страница 21: ...e damage to the fixture do not exceed the rated average life by more than 25 percent The procedure for installing the lamp is described on page 5 After installing the lamp reset the lamp usage counter...

Страница 22: ...omponents to cool completely 2 Wash dirty lenses and filters with isopropyl alcohol A generous amount of regular glass cleaner may also be used but no residues may remain 3 Rinse with distilled water...

Страница 23: ...edium Random strobe slow Shutter open Random opening pulse fast Random opening pulse slow Random closing pulse fast Random closing pulse slow Shutter open Reset fixture see note Shutter open Lamp powe...

Страница 24: ...TC 3200 5600 CTC 3200 4100 White Continuous rotation CW fast slow CCW slow fast Random color Fast Medium Slow Alternate Functions Channel 3 set from 246 to 255 67 different colors in following order w...

Страница 25: ...31 232 255 0 70 0 8 16 24 31 39 47 55 63 70 71 72 72 73 73 74 74 75 75 76 77 78 78 79 79 80 80 81 82 91 92 100 Fixed Gobos Continuous scroll Full positions Open Gobo 1 Gobo 2 Gobo 3 Gobo 4 Gobo 5 Gobo...

Страница 26: ...ode Fast slow Tracking at slow speed overrides PTSP FAST Tracking at fast speed overrides PTSP SLOW Blackout while moving 14 16 0 245 0 251 252 255 0 2 3 245 246 255 Effects Speed Dimmer iris focus an...

Страница 27: ...0 89 G 9 90 102 S TATIC G OBO S HAKE G 9 103 119 G 8 120 136 G 7 137 153 G 6 154 170 G 5 171 187 G 4 188 204 G 3 205 221 G 2 222 238 G 1 239 255 F OCUS infinity 2 meters P RISM out 0 19 19 ccw rotatio...

Страница 28: ...he lamp is ON but no Lamp ON command has been received This can occur if the lamp relay is stuck or if the lamp feedback circuit fails The fixture may be operated but remote lamp on off may be effecte...

Страница 29: ...the fixtures is defective and dis turbs data transmission on the link Bypass one fixture at a time until normal oper ation is regained Do this by unplugging the XLR in and out connectors and connectin...

Страница 30: ...30 Circuit BoardLayout a p p e n d i x d CIRCU IT B OA RD LAYOUT RED BROWN Hard boot jumper XLR pin out jumper Lamp feedback...

Страница 31: ...r fo r m a n c e Light output 8500 lm Center intensity 17 version 234 000 cd Center intensity 23 5 version 127 000 cd R otating gobos Outside diameter 27 8 0 2 mm Maximum image diameter 23 mm Maximum...

Отзывы: