Control Panel
M
A N U A L
C O N T R O L
M a n u a l c o n t r o l (
M A N
)
The manual control menu permits you to do the following without a controller:
•
reset the fixture (
R S T
)
•
turn the lamp on and off (
L O N
,
L o F F
)
•
open, close, and strobe the shutter at 3 speeds (
S H U T
)
•
control the dimmer (
d I M
)
•
move the color wheels to each position and scroll them at 3 speeds (
C O L 1
,
C O L 2
)
•
move the fixed-gobo wheel to each position (
F g o b
)
•
move the rotating-gobo wheel to each position and rotate the gobos at 3 speeds (
R g o b
)
•
control the focus (
F O C U
)
•
control the iris (
I R I S
)
•
insert and rotate the prism (
P R I S
) at 3 speeds, or, if a frost filter is installed, vary the frost (
F R O S
)
•
control pan and tilt (
P A N
,
T I L T
)
A d j u s t m e n t (
A d J
)
The adjustment menu provides manual control for making mechanical adjustments. These should be performed by a
qualified technician. The menu allows you to reset the fixture (
R S T
), turn on and off the lamp (
L
O N
,
L o F F
), con-
trol all effects (FX), and move the mirror to the home and extreme positions (
P A T I
). The
F X
submenu allows you
to:
•
open, close, and strobe the dimmer/shutter (
d I M
)
•
move the color and gobo wheels through their positions (
C O L 1
,
C O L 2
,
F g o b
,
R g o b
)
•
move the focus lens to its extreme positions (
F O C U
)
•
open and close the iris (
I R I S
)
•
insert and rotate the prism (
P R I S
)
S
T A N D
-
A L O N E
S E Q U E N C E S
D e m o n s t r a t i o n p r o g r a m s (
d E M O
)
This menu offers 2 preprogrammed demonstrations. Demo 1 shows each effect individually and in combination with
others. Pan and tilt are static. Demo 2 pans and tilts within a defined area and shows various effect combinations.
Before running demo 1, set the pan/tilt position (
P A N
,
T I L T
) to a good location for viewing the effects and then
focus (
F O C U
) the beam. Select
S E Q
to run the demo. Demo 2 is similar but instead of defining a home position, you
define an area such as a screen or wall by setting the minimum and maximum pan and tilt positions (
M I N P
,
M A X P
,
M I N T
,
M A X T
). Focus the beam in the center of the area.
Te s t s e q u e n c e s
Test sequence (
T S E Q
): Run a general test of all effects.
Printed circuit board test (
S P E C
/
P C B T
): This menu provides 4 tests of the circuit board for service use:
T I
,
T 2
,
T 3
, and
L E d
.
Factory test (
S P E C
/
F T S T
): This menu provides an effects test (
E T S T
), a movement test (
M T S T
), and a sensor
test (
S T S T
) used for quality control. The sensor test includes programs for testing sensors on the color and gobo
wheels (
C O L 1
,
C O L 2
,
R g o b
, and
F g o b
).
U
T I L I T I E S
C a l i b r a t i o n (
C A L
)
The calibration menu allows you to adjust the effects to achieve total uniformity between fixtures: it is not a substitute
for mechanical adjustment. Select dimmer/shutter (
d
O F
), color wheels (
C 1 O F
,
C 2 O F
), rotating-gobo wheel
(
R G O F
), focus (
F O O F
), or fixed-gobo wheel (
F G O F
) and adjust the effect’s offset with the arrow keys. Offsets are
adjustable from 1 to 255 for all effects except the fixed-gobo wheel, which is adjustable from 127 to 129. Press
>
ENTER
@ý
to save the calibration.