1 4
R o b o S c a n 8 1 2
W A R N I N G !
Make sure the fixture is disconnected from AC power.
R o b o S c a n 8 1 2 U S
1.
Remove the cover above the lamp. (6)
2.
Remove the cover (8) above the circuit board.
3.
Locate the connection block next to the circuit board. Right beside it is a
label indicating the proper terminal for each voltage.
4.
With a small screwdriver, loosen the screw in the terminal that holds the
BROWN wire. Remove the brown wire. Tighten the screw. Note: The
BLACK wire must always be connected to the 220 V terminal.
5.
Loosen the screw for the terminal closest to the supply voltage and insert
the BROWN wire. Tighten the screw.
6.
Remove the end plate (5) to access the ballast.
7.
To set the frequency, move the GREY wire on the ballast to the “230-50”
(50 Hz) or “230-60” (60 Hz) terminal. The wire is released and locked by
inserting a small screwdriver in the square hole next to the terminal and
prying back the spring.
8.
Tug lightly on the GREY wire to make sure that it is connected securely.
9.
Reassemble the unit before connecting to AC power.
R o b o S c a n 8 1 2 E U
1.
Remove the cover above the lamp. (6)
2.
Remove the cover (8) above the circuit board.
3.
Move the BROWN transformer wire to the transformer setting shown
above. Do not move the WHITE and BLUE wires from terminal 1.
4.
Remove the end plate (5) to access the ballast.
50 Hz AC Supply
Transformer
Setting
Ballast
Setting
218 - 234 V
230 V
230 V
235 - 240 V
230 V
240 V
241 - 244 V
250 V
240 V
245 - 260 V
250 V
250 V