background image

Operation

7

O

PERATION

3

For optimum performance from your Magnum 2000:

• Keep the machine and the remote control unit away from damp rooms or wet 

conditions.

• Never operate the machine without fluid in the tank, as this may harm the pump 

system. 

• Use clean fluid to avoid clogging of the heating element and damage to the pump. 
• Use Martin fog fluid. This fluid is non- toxic, water-based and specially designed 

for Martin smoke machines. Jem “Pro-Smoke” fluids may be substituted. 

 

( R E M O T E )   C O N T R O L   U N I T

The control unit is secured to the back panel by two thumbscrews. It may be
removed for remote control and placed in a rack or on a table. 

T o   r emo v e  t h e  c on t r o l   u n i t

1 Unscrew the thumbscrews on either side of the control unit and pull it out of

the control unit well. 

2 Use the included cable to connect either one of the 3-pin outputs on the control

unit to the 3-pin input inside the control unit well.

Either of the control unit’s outputs may be used, but not both. To connect additional
machines, use the “Slave output” on the rear panel of the smoke machine.

 

P O W E R

To enable the heater circuit, simply turn the knob on the control unit clockwise until
the POWER LED lights. 

Содержание Magnum Pro 2000

Страница 1: ...Magnum 2000 user manual...

Страница 2: ...2000 Martin Professional A S Denmark All rights reserved No part of this manual may be reproduced in any form or by any means without permission in writing from Martin Professional A S Denmark Printe...

Страница 3: ...life and reliability High pressure pump Variable smoke output Remote control unit with auto timer and memory function 0 10 V control input Slave output for control of multiple units from a single rem...

Страница 4: ...fog fluid only Always ground earth the device electrically Use only a source of AC power that complies with local building and electrical codes and has both overload and ground fault protection Do not...

Страница 5: ...a plug on the mains lead You will have to fit a suitable plug one that fits your local wall outlet before you can connect the machine to the mains The double isolated mains lead on the Magnum 2000 co...

Страница 6: ...Other fluids may clog the heating element or spit from the nozzle To install the fluid tank 1 Place the fluid tank in the Magnum 2000 as shown on page 2 2 Remove the container cap and screw on the tan...

Страница 7: ...O L UNI T The control unit is secured to the back panel by two thumbscrews It may be removed for remote control and placed in a rack or on a table To remove the control unit 1 Unscrew the thumbscrews...

Страница 8: ...n you release the Smoke button smoke emission will continue for another few seconds because the fluid in the heating element is under pressure A UTO TI ME R The auto timer allows you to program output...

Страница 9: ...s to pin 1 on the XLR control input and that the 0 10V output connects to pin 3 The analog control levels are shown below MULTIPLE MA CHINES Whether you operate your Magnum 2000 via the control unit o...

Страница 10: ...cate on the left hand side of the PCB fuse F1 5 Replace the fuse with a new one T 10 A at 230 V T 15 A at 115 V 6 Re assemble the device before connecting to the mains No light in the POWER LED on rea...

Страница 11: ...n dealer for service To reset the thermo switch Warning Before attempting any of the following ensure that the machine is disconnected from mains power and cooled down 1 Remove the fluid tank from the...

Страница 12: ...V model AC voltage 115 V model AC frequency 200 260 V 100 130 V 50 60 Hz Power consumption 1700 W Maximum fluid consumption 0 2 l min Tank capacity 9 5 l 2 5 gall Warm up time 8 10 min Fuse 10 AT at 2...

Отзывы: