INTRODUCTION

The MAGNUM CLUB SMOKE is a system designed for fixed installations
and overcomes the problems associated with installing traditional fog
machines.

Separating the fluid from the vaporising unit allows the Head to be installed
in any location without the need to have access for fluid refills.
The fluid is contained in the wall mountable service module which can be
located away from the heads where access is easy.

The fluid level is monitored electronically and a fluid out indicator is visible at
the front of the service module. This prevents damage to the pumps
occurring due to lack of fluid.

The service module also contains the DMX decoder, allowing the address
setting to be changed without needing access to the heads.

Installation is simple and requires no special tools, since the fluid
connections are made using ‘push-in’ fittings and flexible nylon piping.
Once installed, the system can be operated from the remote control or a
standard DMX 512 compliant lighting console.

FEATURES

Standard system includes two
Heads

Wall mountable Service Module

Remote control included

0 - 10 V analogue control is possible

DMX decoder as standard

10m fluid lines and control cables

Service module can be located up
to 50m from Heads

10L fluid container

Continuous operation from up to 4
Heads

Electronic fluid level sensing and
shutdown

System expansion to 4 Heads

Operation can be linked with JEM
AF1 fan unit

Fluid connections using ‘Push-In’
fittings

MAGNUM CLUB SMOKE SYSTEM

USER
GUIDE

2

SYSTEM EXPANSION

The standard system can be expanded to operate 4 heads and the JEM AF-
1 fan unit.
The additional heads are standard units and require only two additional parts
to allow them to be integrated into the standard two head system. The
maximum separation between two heads connected in this way is 10m.
The control cable is extended using a standard XLR3 cable into the
analogue out of the existing head, and the fluid line is fitted with a ‘T’ adaptor
to provide fluid to the new head.
The AF-1 fan can be connected to the control cable by using the analogue
out of the last head to connect to the analogue in of the AF-1 fan.

FLUID LINE

CONTROL CABLE

‘T’ PIECE

TO Af1

TO SERVICE
MODULE

EXISTING HEAD

NEW HEAD

ANALOGUE IN

MAGNUM CLUB SMOKE SYSTEM

INSTALLATION
INSTRUCTIONS

15

Содержание Magnum Club Smoke System

Страница 1: ...Martin Professional A S Olof Palmes All 18 DK 8200 Aarhus N Phone 45 87 40 00 00 Internet www martin dk Magnum Club Smoke System USER GUIDE AND INSTALLATION INSTRUCTIONS VERSION 1 0...

Страница 2: ...CLUB SMOKE SYSTEM CONNECTIONS MAGNUM CLUB SMOKE SERVICE MODULE REMOTE IN DMX IN DMX OUT CH 2 CH 1 FLUID CH 2 FLUID CH 1 MAINS IN ON OFF PIN ALLOCATIONS CHANNEL 1 2 1 1 1 2 2 2 3 3 3 READY 0 10 V 0 10...

Страница 3: ...ntroller REMOTE CONTROL 16v power supply from service module Standard 0 10V output signal Output level control from 0 to 100 Power On LED Timer cycle LED Timer range Delay time 2sec 18 sec x1 16 sec 2...

Страница 4: ...all mountable Service Module Remote control included 0 10 V analogue control is possible DMX decoder as standard 10m fluid lines and control cables Service module can be located up to 50m from Heads 1...

Страница 5: ...use with the machine the voltage setting is printed on the serial label Always read the user guide before operating the machine smoke machines need to be operated carefully to avoid risk Do not remov...

Страница 6: ...y require 15 minutes to reach operating temperature The LEDs on the rear panels of the heads show the status of the heating cycle When the green LED is on the head is ready to make smoke If the remote...

Страница 7: ...he timer functions Switching the heaters in the Heads to standby no power used OUTPUT DELAY TIME RUN TIME FOG STAND BY TIMER VALUE TIMER ON OFF FOG BUTTON STAND BY BUTTON TIMER VALUE BUTTON TIMER ENGA...

Страница 8: ...output is automatically reduced The output will remain at this level until the DMX signal is reduced or the fluid is exhausted There is no possibility of damage since the electronic fluid level senso...

Страница 9: ...into the push in fitting on the back panel HEAD INSTALLATION CONTROL CABLE FROM SERVICE MODULE POWER CABLE FLUID LINE MAGNUM CLUB SMOKE SYSTEM INSTALLATION INSTRUCTIONS 10 SYSTEM EXPANSION OPTIONS Alt...

Страница 10: ...ee the components that make up the complete system This is the standard system expansions will be dealt with later in the guide For detailed instructions on installing each part of the system refer to...

Отзывы: