SPECIFICATION

HEAD

1KW heater
Copper vaporizing coil
High pressure fluid delivery
Electronic Temperature control using thermocouple
Analogue remote control system
Solenoid operated flow control valve
Adjustable mounting bracket
Maximum distance to service module 50 m
Maximum height above service module 10m

SERVICE MODULE

Oscillating piston high pressure fluid pumps
Low fluid detection by electronic sensor
DMX512 decoder:

Required Channels = 1
Output is proportional for all levels above 10%
Channels supported = 1 to 512
Valid start codes = 0 (dimmer data only)
Full framing error detection implemented

Analogue control via standard Martin Multifunction Controller.

REMOTE CONTROL

16v power supply from service module
Standard 0 - 10V output signal
Output level control from 0 to 100%
Power On LED
Timer cycle LED
Timer range:

Delay time

2sec - 18 sec (x1)

16 sec - 2 min24sec(x8)

Run time

2sec - 18 sec (x1)

16 sec - 2 min24sec(x8)

MAGNUM CLUB SMOKE SYSTEM

16

System Layout Guidelines

Head Installation

Service Module Installation

DMX Settings

Commissioning The System

Maintenance

System Expansion

Specifications

©

Martin Professional A/S, Denmark.

2004

All rights reserved. No part of this manual may be reproduced, in any form or
by any means, without permission in writing from Martin Professional A/S,
Denmark.

MAGNUM CLUB SMOKE SYSTEM

USER GUIDE CONTENTS

INSTALLATION INSTRUCTIONS CONTENTS

Introduction

Features

Safety Guidelines

System Components

Remote Control Operation

DMX Operation

System Expansion Options

Fault Finding

1

Содержание Magnum Club Smoke System

Страница 1: ...Martin Professional A S Olof Palmes All 18 DK 8200 Aarhus N Phone 45 87 40 00 00 Internet www martin dk Magnum Club Smoke System USER GUIDE AND INSTALLATION INSTRUCTIONS VERSION 1 0...

Страница 2: ...CLUB SMOKE SYSTEM CONNECTIONS MAGNUM CLUB SMOKE SERVICE MODULE REMOTE IN DMX IN DMX OUT CH 2 CH 1 FLUID CH 2 FLUID CH 1 MAINS IN ON OFF PIN ALLOCATIONS CHANNEL 1 2 1 1 1 2 2 2 3 3 3 READY 0 10 V 0 10...

Страница 3: ...ntroller REMOTE CONTROL 16v power supply from service module Standard 0 10V output signal Output level control from 0 to 100 Power On LED Timer cycle LED Timer range Delay time 2sec 18 sec x1 16 sec 2...

Страница 4: ...all mountable Service Module Remote control included 0 10 V analogue control is possible DMX decoder as standard 10m fluid lines and control cables Service module can be located up to 50m from Heads 1...

Страница 5: ...use with the machine the voltage setting is printed on the serial label Always read the user guide before operating the machine smoke machines need to be operated carefully to avoid risk Do not remov...

Страница 6: ...y require 15 minutes to reach operating temperature The LEDs on the rear panels of the heads show the status of the heating cycle When the green LED is on the head is ready to make smoke If the remote...

Страница 7: ...he timer functions Switching the heaters in the Heads to standby no power used OUTPUT DELAY TIME RUN TIME FOG STAND BY TIMER VALUE TIMER ON OFF FOG BUTTON STAND BY BUTTON TIMER VALUE BUTTON TIMER ENGA...

Страница 8: ...output is automatically reduced The output will remain at this level until the DMX signal is reduced or the fluid is exhausted There is no possibility of damage since the electronic fluid level senso...

Страница 9: ...into the push in fitting on the back panel HEAD INSTALLATION CONTROL CABLE FROM SERVICE MODULE POWER CABLE FLUID LINE MAGNUM CLUB SMOKE SYSTEM INSTALLATION INSTRUCTIONS 10 SYSTEM EXPANSION OPTIONS Alt...

Страница 10: ...ee the components that make up the complete system This is the standard system expansions will be dealt with later in the guide For detailed instructions on installing each part of the system refer to...

Отзывы: