10
Point 2: Down Outlet
Point 1: Up Outlet
Point 4: Directional valve Inlet
Point 3 : Airbag outlet
4.3 Plumbing box retubing for Bi
-
Directional Control
The bi
-
directional control configuration requires a 2
-
valve system (Part No: SC
-
ASSEMBLY
-
2).
The plumbing box valve connection needs to be reconfigured as described bellow for bi
-
directional control.
Step 1: Disconnect the tube ends only at the points shown in the picture. Don
’
t disconnect the
other ends of the tubes.
Point 1: Up outlet
Point 2: Down outlet
Point 3: Airbag Outlet
Point 4: Directional valve inlet
Complete plumbed box is shown from left and right views in bellow pictures.
Check for any
leaks before closing the plumbing box cover.