55908059-01
17
C
S1 probe alarm manag.:
1= No action
2= Valve forced closed
3= Valve at
fixed posit.
4= Use backup probe S3
Valve at fixed
position
-
-
-
I
24
151
C
S2 probe alarm manag.:
1= No action
2= Valve forced closed
3= Valve at
fixed posit.
4= Use backup probe S4
Valve at fixed
position
-
-
-
I
25
152
C
S3 probe alarm manag.:
1= No action
2= Valve forced closed
3= Valve at
fixed posit.
No action
-
-
-
I
26
153
C
S3 probe alarm manag.:
1= No action
2= Valve forced closed
3= Valve at
fixed posit.
No action
-
-
-
I
27
154
C
Unit of measure: °C/K/barg; °F/psig
°C(K), barg
-
-
-
I
21
148
A
DI1 configuration
1= Disabled
2= Valve regulation optimization after defrost
3= Discharged battery alarm management
4= Valve forced open (at 100%)
5= Regulation start/stop
6= Regulation backup
7= Regulation security
Regulation
start/stop
(tLAN-RS485)
/ Regulation
backup
(pLAN)
-
-
-
I
85
212
A
Language: Italian; English
English
-
-
-
-
-
-
PROBES
C
S1 calibration o
ff
set
0
-85(-1233), -85
85(1233), 85
barg (psig)
mA
A
34
33
C
S1 calibrat gain on 4-20 mA
1
-20
20
-
A
36
35
C
S1 pressure MINIMUM value
-1
-20 (-290)
S1 pressure
MAXIMUM
value
barg (psig)
A
32
31
C
S1 pressure MAXIMUM value
9.3
S1 pressure
MINIMUM
value
200 (2900)
barg (psig)
A
30
29
C
S1 alarm MIN pressure
-1
-20 (-290)
S1 alarm MAX
pressure
barg (psig)
A
39
38
C
S1 alarm MAX pressure
9.3
S1 alarm MIN
pressure
200 (2900)
barg (psig)
A
37
36
C
S2 calibration o
ff
set
0
-20 (-36), -20
20 (36), 20
°C (°F), volt
A
41
40
C
S2 alarm MIN temperat
-50
-85(-121)
S2 alarm MAX
temp.
°C(°F)
A
46
45
C
S2 alarm MAX temperat
105
S2 alarm MIN
temp.
200 (392)
°C(°F)
A
44
43
CONTROL
A
Superheat set point
6
LowSH:
threshold
180 (324)
K(°R)
A
50
49
A
Valve opening at start-up
50
0
100
%
I
37
164
C
Valve opened in standby
(0=disabled=valve closed; 1=enabled = valve open according to
parameter
“Valve position in stand-by”)
1=enabled =
valve open
according to
parameter
“Valve
position in
stand-
by”
0
1
-
D
23
22
Содержание A2LCELLARMATCH
Страница 1: ...55908059 01 A2LCELLARMATCH TECHNICAL MANUAL ...
Страница 12: ...55908059 01 12 2G CONDENSING UNIT WIRING DIAGRAMS ...
Страница 14: ...55908059 01 14 ...
Страница 22: ...55908059 01 22 2K COMPONENT IDENTIFICATION SMC ...
Страница 31: ...55908059 01 31 3H EVAPORATOR WIRING DIAGRAM 3I REFRIGERANT SYSTEM SCHEMATIC DIAGRAM ...