10 of 32
104 S. 8th Ave. Marshalltown, IA Phone 800-888-0127 / 641-753-0127 • Fax 800-477-6341 / 641-753-6341 www.MARSHALLTOWN.com
WS2569
MAINTENANCE
After each use, ensure the Spin Screed® is cleaned and stored carefully. Find a secure location for the Pipe to prevent any
objects from falling on or damaging it.
After every three to four uses, lubricate the Dead End Pipe Adapter through the grease fitting using a standard lever-
action grease gun.
After each use, blow pressurized air into the motor enclosure to ensure there is no debris buildup that could potentially
compromise the usage of the motor.
TROUBLESHOOTING
If the Spin Screed® is not spinning or functioning properly, refer to the following guide to diagnose and resolve your issue.
• Check if the motor shank is tightly connected to the chuck. If tightening is required, use the included chuck key to
fully tighten the chuck to the motor shank.
• Check if the end plugs are fully tightened. Tighten them if required.
• Ensure the motor speed is set at the manufacturer default slow speed (300 RPM), and that it has not been shifted
into the high speed (1200 RPM). High speed will not result in better performance and may overheat the motor.
• Refer to the motor manufacturer’s manual for additional troubleshooting regarding the specific device.
ITEM
PART#
Dead End Pipe Adapter
SPNDE
Live End Pipe Adapter
SPNLE
Power Head*
SPNRPH
Pipe**
SPNP4 – SPNP22
*Handle & Motor enclosure with Power Head
**Pipe available from 4’ to 22’ in even numbers
PARTS AVAILABLE FOR REPLACEMENT