background image

OWNER’S MANUAL  -  

RAH-123M, 183M

12

Complete Installation

NOTICE: 

Handle air conditioner gently.

1. Insert air conditioner into cabinet.

3. Install ground screws on both sides of cabinet .
4. Insert front tabs of front panel into top of cabinet and swing

front into place.

5. Attach bottom front of panel with front panel screws. Replace

control knobs (on some models).

NOTICE: 

For through-the-wall installations, if needed, install

molding around room side of cabinet.

6. Plug into a grounded 3 prong outlet.
7. Press RESET on the power supply cord plug.

WARNING

Excessive Weight Hazard

Use two or more people to move and install 

air conditioner.
Failure to do so can result in back or other injury.

WARNING

Electrical Shock Hazard

Install two ground screws on both sides of cabinet.
Failure to do so can result in death or electrical shock.

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 

fire, or electrical shock.

WARNING

12

Содержание Comfort-Aire RAH-123M

Страница 1: ...www marsdelivers com OWNER S MANUAL Room Air Heat Pump with R 410A RAH 123M RAH 183M...

Страница 2: ...ates a hazardous situation that if not avoided could result in death or serious injury Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important bu...

Страница 3: ...by phone contact an authorizedGREE brandservicer Contactandservice will be at your expense SafetyInformation Be sure electrical service is adequate for chosen model of air conditioner Complete electr...

Страница 4: ...nimals unable to react to Instructions for installation and use of this product are provided by the manufacturer product failure Failure of unattended air conditioner may result in extreme heat in are...

Страница 5: ...al or in the mounting kit assembly Follow these instructions carefully Keep these instructions with this manual for future reference Your unit will be one of the following three designs Unit with a wi...

Страница 6: ...IG H LOW AUT O PO WE R FAN SPE ED MO DE COO L ENE RGY SAV ER FAN ONL Y HEA T 1 2 4 HR TEM P T IME R Set TIM ER MED HIGH LOW AUT O POW ER FAN SPE ED MO DE COO L ENE RGY SAV ER FAN ONL Y HEA T 1 24 HR T...

Страница 7: ...3 lbs IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of fire electrical shock or injury when using your air conditioner follow these basic precautions SAVE THESE INSTRUCTIONS Unplug air cond...

Страница 8: ...irements are listed in the chart below Follow the requirements for the type of plug on the power supply cord A min B min 27 16 4 A 16 B 22 C Wood thickness A B Power supply cord 115 volt 103 5 min 126...

Страница 9: ...e of the art electronics that sense leakage current If the cord is crushed the electronics detect leakage current and power will be disconnected in a fraction of a second To test your power supply cor...

Страница 10: ...w Installation on some models NOTICE Handle air conditioner gently Be sure your air conditioner cabinet does not fall out of the opening during installation or removal The location where the power cor...

Страница 11: ...adhesive seal Attach foam adhesive seal along the bottom of the curtain bottom channel Install Cabinet into Window Handle air conditioner gently Be sure your air conditioner cabinet does not fall out...

Страница 12: ...ht hand curtain Complete Window Installation 1 Insert foam seal behind the top of the lower window sash and against the glass of the upper window 2 Place window lock bracket on top of lower window and...

Страница 13: ...the wall opening Square and level frame 6 Attach frame securely to the wall Install Cabinet into Wood Frame 1 Insert cabinet into the framed wall opening The top of the cabinet should extend into the...

Страница 14: ...nd room side of cabinet 6 Plug into a grounded 3 prong outlet 7 Press RESET on the power supply cord plug WARNING Excessive Weight Hazard Use two or more people to move and install air conditioner Fai...

Страница 15: ...nnormalconditionstheunitcanevaporatethe water as fast as it is removed from the indoor air However in very humid conditions excess amounts of water may drip off the unit chassis If this proves to be a...

Страница 16: ...ure when in Heat Cool Energy Saver mode Shows time remaining on the delay timer Shows the room temperature when in Fan Only mo de The Set light will turn on while setting 1 2 5 6 3 4 7 Controls Mode P...

Страница 17: ...ote controller When unit is on each time you press the button on remote controller the sending signal icon on the display of remote controller will blink once If the air conditioner gives out a beep s...

Страница 18: ...1 SPEED 2 SPEED 3 SPEED 4 AUTO FAN button 4 Press this button to turn on up down air swing SWING button 5 Under Cool Heat mode press this button to turn on Sleep function Press this button to cancel...

Страница 19: ...required When you don t use remote controller for a long time please take out the batteries If the display on remote controller is fuzzy or there s no display please replace batteries reinstall remove...

Страница 20: ...rty air filter Normal for low outdoor temperatures Clean air filter by vacuuming or washing with water and mild soap Turning Temperature Control to warmer setting reduces occurrence and duration of fr...

Страница 21: ...ditioners feature a slide out chassis Chassis and front cover must be re moved from outer case for installation In order to reinstall the chassis and re attach the air conditioner front cover the inst...

Страница 22: ...uterCaseinOpening Place outer case in opening flush against one side of opening Use carpenter s level and ensure case is level from side to side and has a 3 8 inch slope from front to back back of cas...

Страница 23: ...ng to ensure free air flow to the side louvers This can be accomplished by chamfering the vertical portions of the outside opening as shown Ventilation louvers on top of case must not be obstructed Do...

Страница 24: ...warranty begins on the date of shipment from the factory REMEDY PROVIDED BY THE LIMITED EXPRESS WARRANTY The sole remedy under the Limited Warranty is replacement of the defective unit Labor to diagno...

Страница 25: ...WKH LQVWDOOHU LV UHVSRQVLEOH IRU YHULI LQJ GLPHQVLRQDO GDWD RQ WKH DFWXDO SURGXFW SULRU WR EHJLQQLQJ DQ LQVWDOODWLRQ SUHSDUDWLRQV QFHQWLYH DQG UHEDWH SURJUDPV KDYH SUHFLVH UHTXLUHPHQWV DV WR SURGXFW S...

Отзывы: