Access Panels Removal
This unit is equipped with four [4] different access panels: left and right vertical panels, and two [2] firebox cavity cover plates
that are located inside the firebox (behind the side liners). NOTE: Cavity cover plates are not installed at the factory.
Vertical Access Panel
The Vertical Access Panel completely lifts off the unit to provide unobstructed access to the valve assembly, as well as the
fan speed switch and Thermodisc (optional). To remove, simply lift the panel up off the locating dimples and swing the bottom
outwards and away from the fireplace.
Use caution when handling the panel to ensure that the paint is not scratched.
To
reinstall:
1. Insert the upper tab into the Access Panel Slot as shown in Figure 11. A small guide is provided to assist in positioning
the upper tab.
2. Swing the lower portion of the panel in so that the holes line up with the lower locating dimples. Carefully set the panel
onto the dimples.
Cavity Access Cover Plate
The Cavity Access Cover Plates provide access to the electrical
box and fan assembly (optional). They are located behind the
side liner panels and are sealed with
Millpac
and fastened in
place with ten [10] screws.
NOTE:
Cavity cover plates are not
installed at the factory. They need to be installed by the
installer. To remove, simply unfasten the screws and remove.
When reinstalling:
1. Ensure that the area is clean and free from old sealant
material.
2. Generously apply high temperature
Millpac
to the area and
fasten the access plate back with the ten [10] DT screws.
Ensure that the plate is sufficiently sealed and secured.
Figure 11 – Installation guide of the Vertical Access Panels.
Figure 12 - Cavity Access Plate tightening sequence.