Burner System Maintenance
It is recommended to annually inspect and clean the Burner System to prevent malfunction and / or sooting. This
operation should be performed by your dealer or a qualified technician.
-CAUTION-
Before servicing the burner system ensure that the gas supply is turned OFF and disconnect all
electrical connections to the appliance. Allow the appliance to cool to room temperature. Note
that the pilot assembly may be hot in an intermittent or standing-pilot system—even if the main
burner was never on. Exercise caution when working within the area.
-ALL WORK SHOULD BE PERFORMED BY A QUALIFIED AND CERTIFIED TECHNICIAN-
Monthly Flame Inspection
It is recommended to turn on the unit at least once a month and inspect the flame pattern to ensure there are no problems
with the burner tube. The pilot flame should also be inspected monthly to ensure proper operation.
Flame should appear similar to the above picture.
Conversion Kit Instructions – PART A
Kit Number
Description
Pilot Orifice
Burner Orifice
Brass (1000-255)
Brass Nipple
Air Shutter Hi/Lo Regulator
34IDV-CKLP
44IDV-CKLP
LP Conversion
-Millivolt-
1001-P167SI
#30
(977.167)
#51
#50
1000-253closed
1000-253closed
1/2”
1/2”
1001-P202SI
1001-P202SI
34IDV-CKNG
44IDV-CKNG
NG Conversion
-Millivolt-
1001-P165SI
#51
(977.165)
#35
#32
1000-253closed
1000-253closed
3/16”
3/16”
1001-P201SI
1001-P201SI
34IDV-CKLPI
44IDV-CKLPI
LP Conversion
-IPI-
1001-P168SI
#35
(977.168)
#51
#50
1000-253closed
1000-253closed
1/2”
1/2”
1002-P014SI
1002-P014SI
34IDV-CKNGI
44IDV-CKNGI
NG Conversion
-IPI-
1001-P166SI
#62
(977.166)
#35
#32
1000-253closed
1000-253closed
3/16”
3/16”
1002-P016SI
1002-P016SI
Refer to “
Gas Specifications Chart
” for inlet pressures and input ratings. Clock meter to verify input rate. Place conversion label
as close to converted gas control as possible. Refer to lighting instructions to verify the normal operating sequence of the ignition
system. IMPORTANT: Always check for gas leaks with a soap and water solution. DO NOT USE OPEN FLAME FOR LEAK
TESTING.
Pilot Shield area
must be kept clear.
43