10
15-Channel Operation
(continued)
Channel Function
Value
Description
13
Prism Rotation
000–127
Indexed position, 0° (
000
) to 360° (
127
)
128–189
Counterclockwise prism rotation, fast (
128
) to slow (
189
)
190–193
Stop at current position
194–255
Clockwise prism rotation, slow (
194
) to fast (
255
)
14
Macro Functions
000–007
No function
008–023
Automatic movement 1
024–039
Automatic movement 2
040–055
Automatic movement 3
056–071
Automatic movement 4
072–087
Automatic movement 5
088–103
Automatic movement 6
104–119
Automatic movement 7
120–135
Automatic movement 8
136–151
Sound-active movement 1
152–167
Sound-active movement 2
168–183
Sound-active movement 3
184–199
Sound-active movement 4
200–215
Sound-active movement 5
216–231
Sound-active movement 6
232–247
Sound-active movement 7
248–255
Sound-active movement 8
15
Control Functions
All functions are executed
after 2 seconds.
000–049
No function
050–059
Blackout during pan/tilt or color/gobo change
060–069
Disable blackout during pan/tilt or color/gobo change
070–079
Blackout during pan/tilt
080–089
Disable blackout during pan/tilt
090–099
Blackout during color change
100–109
Disable blackout during color change
110–119
Blackout during gobo change
120–129 Disable
blackout
during gobo change
130–139
No function
140–149
Reset pan/tilt
150–169
Reset color/gobo/focus/prism
170–199
No function
200–209
Reset all
210–255
No function