Copyright by Servizio Clienti ANGELO PO Spa
41
E06:12
The output current too high
check that the motor is free to move a
nd doesn’t
touch any other item
E06:13
Found scattered current too high
between one of the phases and earth.
check that one or more phases of the motor
power supply are not short circuited with the
mass
E06:33
Automatic restart failed
There was an alarm 4, 5, 6, 7, 8, 12 or 63, but
the automatic restart was unsuccessful. Remove
the cause of these alarms and restart.
E06:38
Phase U short circuited with GND
check the correct connection of the motor and
check that the phase U of motor supply is not
short circuited to the GND
E06:39
Phase V short circuited with GND
check the correct connection of the motor and
check that the phase V of motor supply is not
short circuited to the GND
E06:40
Phase W short circuited with GND
check the correct connection of the motor and
check that the phase W of motor supply is not
short circuited to the GND
E06:41
between phases a UV excess current
flows
check the correct connection of the motor and
that the phases U and V of the motor power
supply are not short circuited together
E06:42
between phases a UW excess current
flows
check the correct connection of the motor and
that the phases U and W of the motor power
supply are not short circuited together
E06:43
between phases a VW excess current
flows
check the correct connection of the motor and
that the phases V and W of the motor power
supply are not short circuited together
E06:64
High current limit exceeded 150% for 1
minute or 200% for 3 seconds
check that the motor is free to move
and doesn’t
touch and other item
E06:70
inverter power section faulty
Check the inverter voltage (220VAC)
Содержание ANGELO PO COMBISTAR FX
Страница 1: ...1 Rev 0 ...
Страница 6: ...Copyright by Servizio Clienti ANGELO PO Spa 6 1 COMMERCIAL MODEL NUMBER ...
Страница 7: ...Copyright by Servizio Clienti ANGELO PO Spa 7 FX Models table ...
Страница 10: ...Copyright by Servizio Clienti ANGELO PO Spa 10 OVEN CONNECTION DIAGRAM FX 61 G3 ...
Страница 14: ...Copyright by Servizio Clienti ANGELO PO Spa 14 2 FUNCTIONAL DIAGRAM COMBI OVEN 6 7 10 1 9 5 11 12 13 14 15 ...
Страница 19: ...Copyright by Servizio Clienti ANGELO PO Spa 19 2 4 Steam producing operation injectors code ...
Страница 21: ...Copyright by Servizio Clienti ANGELO PO Spa 21 ...
Страница 44: ...Copyright by Servizio Clienti ANGELO PO Spa 44 ...
Страница 46: ...Copyright by Servizio Clienti ANGELO PO Spa 46 Fuses on Power Board ...
Страница 61: ...Copyright by Servizio Clienti ANGELO PO Spa 61 ...
Страница 67: ...Copyright by Servizio Clienti ANGELO PO Spa 67 Functional diagram gas system ...
Страница 104: ...Copyright by Servizio Clienti ANGELO PO Spa 104 ...
Страница 151: ...Copyright by Servizio Clienti ANGELO PO Spa 151 PICTURE 7 PICTURE 8 PICTURE 5 PICTURE 6 ...
Страница 162: ...Copyright by Servizio Clienti ANGELO PO Spa 162 6 15 Roll In adjustment RX201 RX202 ...
Страница 163: ...Copyright by Servizio Clienti ANGELO PO Spa 163 ...