5.3. Clean test
The procedure for testing pumps (available in the service menu) is used to verify the
working of the washing circuit.
It consists of 4 steps:
step 1
– detergent pump working
During this stage it is possible to check that the detergent pump works and that after
a few minutes the liquid level in the tank increases (if the suction pipe is empty, it
takes about 2-3 minutes to fill it).
step 2
– sanitizer pump working
During this stage it is possible to check that the sanitizer pump works and after a few
minutes the liquid level in the tank increases (if the suction pipe is empty, it takes
about 2-3 min to fill it).
step 3
– rinsing
During this stage it is possible to check that there are no leaks in the connections of
the pipes, no obstructions into the nozzles and that the water pressure is regulated.
Step 4
– tank emptying
During this stage it is possible to check that the liquid level into the tank drops until
the tank is empty.
During all stages the status of the float shows on the display: it must be open when the
tank is empty, it must be closed when the liquid level in the tank exceeds half.
Содержание ANGELO PO COMBISTAR FX
Страница 1: ...1 Rev 0 ...
Страница 6: ...Copyright by Servizio Clienti ANGELO PO Spa 6 1 COMMERCIAL MODEL NUMBER ...
Страница 7: ...Copyright by Servizio Clienti ANGELO PO Spa 7 FX Models table ...
Страница 10: ...Copyright by Servizio Clienti ANGELO PO Spa 10 OVEN CONNECTION DIAGRAM FX 61 G3 ...
Страница 14: ...Copyright by Servizio Clienti ANGELO PO Spa 14 2 FUNCTIONAL DIAGRAM COMBI OVEN 6 7 10 1 9 5 11 12 13 14 15 ...
Страница 19: ...Copyright by Servizio Clienti ANGELO PO Spa 19 2 4 Steam producing operation injectors code ...
Страница 21: ...Copyright by Servizio Clienti ANGELO PO Spa 21 ...
Страница 44: ...Copyright by Servizio Clienti ANGELO PO Spa 44 ...
Страница 46: ...Copyright by Servizio Clienti ANGELO PO Spa 46 Fuses on Power Board ...
Страница 61: ...Copyright by Servizio Clienti ANGELO PO Spa 61 ...
Страница 67: ...Copyright by Servizio Clienti ANGELO PO Spa 67 Functional diagram gas system ...
Страница 104: ...Copyright by Servizio Clienti ANGELO PO Spa 104 ...
Страница 151: ...Copyright by Servizio Clienti ANGELO PO Spa 151 PICTURE 7 PICTURE 8 PICTURE 5 PICTURE 6 ...
Страница 162: ...Copyright by Servizio Clienti ANGELO PO Spa 162 6 15 Roll In adjustment RX201 RX202 ...
Страница 163: ...Copyright by Servizio Clienti ANGELO PO Spa 163 ...