MR 150M–1050M - PLC CONTROLLER
Please Circle and/or Fill in the Appropriate Data for Future Reference:
Softener Model:
MR _____________
System Size:
Single
/
Twin
/
Triple
/
Quad
Meter Size:
________________
Configuration: Timeclock
/
Twin Alt
/
Parallel
/
Progressive
Unit Capacity:
________________ Grains
Feed Water Hardness:
________________ Grains
Treated Water:
________________ Gallons/Liters
BW/Regen Time
________________ AM/PM or OFF
Additional Notes: ________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
IMPORTANT PLEASE READ:
�
Warranty of this product extends to manufacturing defects.
�
The information, specifications and illustrations in this manual are based on the latest
information available at the time of printing. The manufacturer reserves the right to make
changes at any time without notice.
�
This product should be installed by a plumbing professional on potable water systems only.
�
This product must be installed in compliance with all local and state and municipal plumbing and
electrical codes. Permits may be required at the time of installation.
�
If operating pressure exceeds 100 psi a pressure reducing valve must be installed. If operating
pressure drops below 30 psi a booster pump must be installed.
�
Do not install the unit where temperatures may drop below 32°F or rise above 100°F.
�
A prefilter should be used on installations in which free solids are present.
�
A constant voltage of 120V/60Hz (unless otherwise specified) must be supplied to the controller
to maintain proper function.
�
Union or flange fittings are recommended at the control valve's inlet, outlet, and drain
connections
�
If distance of drain line is over a 10 ft. vertical or 25 ft. horizontal run, increase drain line one
pipe size over that provided on the control valve.
�
Do not make a direct connection to the drain. Provide an air gap of at least four times the
diameter of the pipe to conform to sanitation codes and to permit observation of the flow.
Page 1
MR 150M–1050M PLC
Содержание MR Series
Страница 7: ...MR 150M 1050M PLC CONTROLLER SYSTEM INFORMATION 4 Page 4 MR 150M 1050M PLC INSTALLATION ...
Страница 11: ...MR 150M 1050M PLC CONTROLLER INSTALLATION 8 TUBING DIAGRAM VALVE NEST MULTITANK ASCO SOLENOID ...
Страница 31: ...MR 150M 1050M PLC CONTROLLER OPERATION 28 PAGE 28 FLOW DIAGRAM Page 28 MR 150M 1050M PLC OPERATION ...
Страница 36: ...MR 150M 1050M PLC CONTROLLER MAINTENANCE 33 ...
Страница 37: ...MR 150M 1050M PLC CONTROLLER MAINTENANCE 34 ...
Страница 38: ...MR 150M 1050M PLC CONTROLLER MAINTENANCE 35 ...
Страница 39: ...MR 150M 1050M PLC CONTROLLER MAINTENANCE 36 ...
Страница 40: ...MR 150M 1050M PLC CONTROLLER MAINTENANCE 37 ...
Страница 41: ...MR 150M 1050M PLC CONTROLLER MAINTENANCE 38 ...
Страница 42: ...MR 150M 1050M PLC CONTROLLER MAINTENANCE 39 ...
Страница 51: ...MR 150M 1050M PLC CONTROLLER 48 NOTES ...
Страница 52: ...2227 South Street P O Box 044170 Racine WI 53404 7003 www Marlo Inc com 8 217 R5 ...