29
Maintenance
Belt Replacement
Always shut off electrical power to the tower fan motor prior to
performing any maintenance on the tower. Any electrical switches
should be locked out and tagged out to prevent others from turning
the power back on.
Do not mix old and new belts. On multiple belt drives, replace all belts
at the same time. Do not mix belts from different manufacturers.
Check bolts for corrosion and damaged threads as they are removed.
Replace as required.
1.
Loosen but do not remove, bolts attaching the motor bracket to top of
the support beam.
2.
Remove tension on belt by loosening the tension nut.
3.
Cut through belts and remove.
4.
Loosen but do not remove bolts from top bearing. Be sure all threads
on nuts are fully engaged.
▲
▲
▲
Warning
▲
▲
▲
Note
MOTOR
1
2
5.
Remove bolts from bottom bearing. Pull bearing away from support,
and slide belt past bearing.
6.
Loosely install bolts in bottom bearing. Be sure all threads on nuts
are fully engaged.
7.
Remove bolts from top bearing. Pull bearing away from support,
and slide belts past top bearing. Install bolts in top bearing.
➠