![Marley MP 100 VFN Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/marley/mp-100-vfn/mp-100-vfn_operating-and-assembly-instructions_1729445007.webp)
ENGLISH
Connection diagram
Technical Data*
Fan P12 (MP 100 VFN)
Protection class/type:
IP 24
Mains voltage:
230 V ~50 Hz
Max. air temperature:
40 °C
Level:
1
2
3
4
5
6
Power consumption W:
1.9
2.7
3.4
4.3
5.8
7.1
Noise level dB (A) 3 m:
25
32.5
36
38.5
43
45
Output m³/h
50
65
75
85
100
110
Pressure build-up Max
Pa:
5
10
15
15
20
25
Fans running time when connected to L1
Manual turn-on
time (L1 active)
Post-run timer
0–2 min
No overrun
2–10 min
5 min
10–15 min
10 min
15–20 min
15 min
Over 20 min
15 min
* Subject to technical modifications
Automatic mode, controlled by
humidity sensor
Automatic mode and manual mode,
unit runs as long as it is turned on –
plus overrun time (when turned on for
longer than 2 min)
7
After being connected to the power supply,
the ventilator runs for up to 30 minutes and
adapts to the ambient humidity.
Содержание MP 100 VFN
Страница 3: ...A B C D E ...