Ensure that all electric power is turned off before carrying out any work.
The electrical connections must be carried out by a qualified electrician
and must comply with the relevant local regulations. The voltage and
frequency of the power supply must comply with the fan's specifications.
The installation site must have an all-pole disconnecting device with a
contact opening width of at least 3 mm. The fans are double-insulated
and do not require a protective earth conductor.
If operated near a fireplace with chimney, care must be taken to ensure
that sufficient air can enter the room being ventilated. In rooms with high
humidity, installation must be done in accordance with DIN/VDE 0100
T701. Use a soft brush or damp cloth to clean, do not use any solvents.
Installation
1.
Install the duct in the wall or ceiling. For wall installation ensure there
is a slight gradient (~2°) towards the outside. For ceiling installation
you must insulate the air duct if it passes through unheated areas.
2.
Remove the cover from the casing by unscrewing in an anti-
clockwise direction. Unscrew the two lower screws [A] and remove
the inner cover [B] from the casing [C].
3.
Unscrew the middle cover [D] and cut out the cable feed-through at
one of the sections [E] using a knife, round off sharp edges. Interrupt
the building's power supply and feed the power cable through the
casing from the back. Protect power cable using the cable strain
relief when cabling on top of plaster. Screw the fan into place on the
wall or ceiling.
4.
Connect power cable in accordance with the connection diagram.
Automatic mode = permanent phase on L
Automatic plus manual mode = permanent phase on L plus switched
phase on L1
5.
Re-assemble middle cover [D] and inner cover [B] and turn on the
building's power supply again.
6.
Adjusting volumetric flows:
Adjustment mode is activated by simultaneously pressing "+" and
"-" for three seconds. Fan settings can be adjusted to the respective
installation situation by pressing " +" or " -".
7.
Replace cover.
ENGLISH
GB
Please read these assembly instructions carefully
before starting the installation.
Recommendation/installation situation:
Ventilation distance
(0.5–3 m)
Normal
Whisper mode
Up to 0.5 m through exterior
wall
4
1
1.5 m with 1 bend
5
2
1.5–3 m with 2 bends
6
3
6