Marley K151FC Скачать руководство пользователя страница 3

a. Run a power supply cable into the area above the top of

the wall opening. All wiring must be in accordance with
National and Local electrical codes. Refer to Table 1, 
page 1 for correct wire size.

b. Install a cable clamp in the knockout in the top of back

box.

c. Insert power supply cable through cable clamp, allowing at

least 6" (152mm) of cable length to remain inside the back
box to facilitate connections.

d. Ground the back box by connecting the supply ground wire

to the green ground screw located in the inside top of the
back box.

3. Mounting Back Box

a. Place the back box into wall opening flush with finished

wall surface on bottom and sides of box. (Top flange of
back box should protrude approximately 1/2" (12.7mm)
from finished wall surface).

b. Secure the back box in place with wood screws or nails.

(optional) Installation of back box With 
Surface-Mounting Frame (see Figure 3).

1. Secure back box to wall (with knockouts in upper right 

hand corner) using screws and anchors.

2. Hang the surface-mounting frame on the back box. 

Ensure that the back edge of the surface-mounting 
frame is flush against the wall.

noTe:

If heater is located in a high traffic area where it may be

subjected to vandalism or abuse, take extreme care to see that
the box is firmly attached to the wall.

3. Power Supply Wiring

noTe: 

Wiring Compartment Volume - 119"3 (1950cm3). 

a. Run a power supply cable into the area of the upper right

corner of the mounting frame. All wiring must be in accor-
dance to National and local Electrical Codes. Refer to
Table 1 for proper wire sizes.

noTe:

If the wiring is to run through the wall, cut a hole in the

wall near the top of the back box. Run the supply wire through
this hole. Then remove the knockout from the top of the box and
proceed to step c.

b. Remove the knockout on the top side of the frame.

c. Feed the power supply cable through the frame allowing 6"

(152mm) of lead to remain inside the frame 

d. Secure the power supply cable to the back box (using

cable clamps, connector, or other suitable strain relief)
allowing 6”(152mm) of lead to remain inside the inner
housing.

e. Ground the back box by connecting the supply ground

leadwire to the green ground screw located in the inside
top of the back box.

Installation of Heater Assembly and Grille

After back box is completely installed and no further construction
dirt is expected, clean debris from back box, remove heater
assembly from its carton, then refer to Figure 4 and proceed as
follows:

1. Insert the heater assembly into back box, placing the four

mounting holes (with key-hole slots) over the screws in the
back box. Tighten all screws securely.

2. If surface-mounting frame is used, ensure that the frame is

even with all four heater assembly tabs before tightening
screws.

3. Connect the lead wires from the disconnect switch to the

lead wires from the fan deck. (see wiring diagrams) 
After connection, push wires back into opening.

4. Turn thermostat to the extreme counterclockwise position.

5. Mount the grille using four (4) long screws provided. The

screws thread into holes located in the side flanges of the
back box.

6. Push thermostat knob onto thermostat shaft.

Figure 3: Surface Mounting Installation

HANG FRAME
ON BACK BOX

15-5/32"

(385mm)

19"

(482mm)

3-13/16"

(97mm)

MOUNT BACK BOX TO
WALL USING REAR
MOUNTING HOLES.

Figure 4

RECESS BACK
BOX

HEATER
ASSEMBLY

THERMOSTAT

KNOB

GRILLE

1500, 4800, 4000, & 3000 WATT HEATERS

120V, 208V, 240V, OR 277V  (Full wattage heaters can be 
converted to half wattage by removing the red jumper wire 
connecting the top and bottom element terminals.) 

noTe:

Conversion not applicable on K151FC.

3

Содержание K151FC

Страница 1: ...s heater only as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons 11 This heater is intended for comfort heating applications and not intended for use in special environments Do not use in damp or wet locations such as marine or greenhouse or in areas where corrosive or chemical agents are present 12 When installing see I...

Страница 2: ...ng 2 All wiring procedures and connections must be in accordance with the National and Local Codes having jurisdiction and the heater must be grounded 3 Power supply must enter back box through the knockouts See also TOP marking on the back box for proper orientation 4 Verify the power supply voltage coming to heater matches the ratings as shown on the heater nameplate CAuTIon ENERGIzING HEATER AT...

Страница 3: ...Then remove the knockout from the top of the box and proceed to step c b Remove the knockout on the top side of the frame c Feed the power supply cable through the frame allowing 6 152mm of lead to remain inside the frame d Secure the power supply cable to the back box using cable clamps connector or other suitable strain relief allowing 6 152mm of lead to remain inside the inner housing e Ground ...

Страница 4: ...y a qualified repair person MAInTenAnCe InSTruCTIonS It is important to keep this heater clean Your heater will give you years of service and comfort with only minimum care To assure efficient operation follow the simple instructions below user Cleaning Instructions 1 After the heater has cooled a vacuum cleaner with brush attachment may be used to remove dust and lint from exterior surfaces of th...

Страница 5: ... WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS AGREEMENT MARLEY ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR CONSEqUENTIAL DAMAGES ARISING WITH RESPECT TO THE PRODUCT WHETHER BASED UPON NEGLIGENCE TORT S...

Страница 6: ...6 notes notas notes ...

Страница 7: ...s o chispas No lo utilice en áreas en las que se utilice o almacene gasolina pintura o líquidos inflamables 10 Utilice este calefactor únicamente de la manera descrita en este manual Cualquier otra forma de uso no recomendada por el fabricante puede ser causa de incendio choque eléc trico o daños personales 11 Este calefactor está destinado a aplicaciones de calefacción ambiental y no es para util...

Страница 8: ... mismo desde el tablero principal de servicio 2 Todos los procedimientos de cableado y conexiones deben hac erse de conformidad con los códigos nacionales y locales que ten gan jurisdicción y el calefactor debe estar conectado a tierra 3 La alimentación eléctrica debe ingresar a la caja posterior a través de los prepunzonados Verifique también la marca ARRIBA TOP de la caja posterior para asegurar...

Страница 9: ...úe con el paso c b Extraiga el prepunzonado de la cara superior del bastidor c Pase el cable de alimentación eléctrica a través del bastidor dejando 152 mm 6 de cable dentro del bastidor d Asegure el cable de alimentación eléctrica a la caja posterior use abrazaderas o conector para cables u otro alivio de tensiones adecuado dejando 152 mm 6 de cable dentro del alojamiento interior e Conecte a tie...

Страница 10: ...i por alguna razón el control de seguridad contra sobretemperatura no funciona como está previsto Si se activa este fusible térmico el calefactor no volverá a funcionar y debe ser reparado por un técnico de servicio califi cado InSTruCCIoneS de MAnTenIMIenTo Es importante mantener limpio este calefactor Su calefactor le brindará muchos años de servicio y confort con sólo un mínimo de cuidado Para ...

Страница 11: ...PRESA O IMPLÍCITA Y POR LA PRESENTE SE DECLINA Y EXCLUYE DE ESTE ACUERDO TODA GARANTÍA IMPLÍCITA DE COMERCIABILIDAD Y ADECUACIÓN A UN PROPÓSITO PARTICULAR qUE EXCEDA LAS GARANTÍAS EXPRESAS ANTEDICHAS MARLEY ENGINEERED PRODUCTS NO SE HARÁ RESPONSABLE POR DAÑOS CONSIGUIENTES qUE SE PRODUzCAN CON RESPECTO AL PRODUCTO EN BASE YA SEA A NEGLIGENCIA AGRAVIO RESPONSABILIDAD ESTRICTA O CONTRATO Algunos est...

Страница 12: ...12 notes notas notes ...

Страница 13: ... des étincelles électriques Ne l utilisez pas dans des zones où de l essence ou des liquides inflammables sont util isés ou entreposés 10 N utilisez ce radiateur que comme c est décrit dans ce manuel Toute autre utilisation non recommandée par le constructeur peut causer un départ d incendie une commotion électrique ou des blessures corporelles 11 Ce radiateur est prévu pour des applications de ch...

Страница 14: ...tre en conformité avec les normes nationales et locales applicables et le radia teur doit être relié à la terre 3 L alimentation secteur doit entrer dans le boîtier arrière au travers des pastilles à enfoncer Voir également le marquage de HAUT sur le boîtier arrière pour la bonne orientation 4 Vérifiez que la tension du secteur arrivant au radiateur correspond bien aux valeurs spécifiées sur sa pl...

Страница 15: ... alimentation secteur au travers de ce trou Puis enfoncez la pastille en haut du boîtier et passez à l étape C b Enfoncez la pastille sur le côté du dessus de l en cadrement c Passez le câble d alimentation secteur au travers de l en cadrement en laissant 6 152 mm de fils à l intérieur du boîtier arrière d Fixez ce câble sur le boîtier arrière en utilisant passe fils connecteur ou autre attache co...

Страница 16: ...onS d enTreTIen Il est important de garder propre le radiateur Votre radiateur vous fourni ra des années de bon service et de confort avec juste un minimum de soins Pour assurer son fonctionnement efficace suivez les instructions simples ci dessous Instructions de nettoyage par l utilisateur 1 Une fois que le radiateur est froid vous pouvez utiliser un aspirateur avec son accessoire brosse pour él...

Страница 17: ...eux doit être retourné au centre de réparation agréé par Marley le plus près ou au centre de réparation de la société Marley Engineered Products Il sera ensuite gratuitement réparé ou remplacé à notre discrétion et les frais de port de retour seront pris en charge par Marley Il est entendu que cette réparation ou ce remplacement constitue le seul et unique recours disponible auprès de la société M...

Отзывы: