Marley K151FC Скачать руководство пользователя страница 2

2

InSTAllATIon
InSTruCTIonS

Installation of back box in new Construction

1. Mounting Back Box (see Figure 1).

a. Place the back box between two 16"  (406 mm)  center-

to-center wall studs at the desired mounting height but
no closer than 8" (203 mm) to adjacent wall or floor.

noTe: 

If wall studs are spaced greater than 16” on center, addi-

tional framing supports may be necessary.

b. Align back box such that the bottom and sides will be

flush with finished wall surface (top flange of back box
should protrude approximately 1/2" (12.7 mm) from fin-
ished wall surface).

c. Secure the back box in position with wood screws or

nails as shown in Figure 1.

2. Power Supply Wiring (see Figure 1)

noTe:

Wire compartment volume - 119 in

(1950 cm

3

).

a. Run a power supply cable into the knockout area in the

upper right hand corner of the back box. All wiring must be
in accordance with National and Local Electrical Codes.
Refer to Specifications, page 1 for correct wire size.

b. Remove knockout in the top of the back box and install a

cable clamp.

c.  Insert power supply cable through cable clamp, allowing at

least 6" (152 mm) of leads to extend inside the back box. 

d. Ground the back box by connecting the supply ground

lead wire to the green ground screw located in the inside
top of the back box.

Installation of back box in existing Construction

1. Provide a wall opening 14-1/2" (362 mm) wide by 18-1/2"

(470 mm) high at the desired mounting height, but no closer
than 8" (203 mm) to adjacent wall or floor. (see Figure 2.) 

noTe: 

Locate so at least one side of opening is at wall stud.

2. Power Supply Wiring

noTe: 

Wiring Compartment Volume - 119 in3 (1950 cm3).

To prevent a possible fire, injury to persons or damage to the
heater, adhere to the following:

1.

Disconnect  all  power  coming  to  heater  at  main  service
panel before wiring or servicing.

2. All  wiring  procedures  and  connections  must  be  in 

accordance  with  the  National  and    Local  Codes  having 
jurisdiction and the heater must be grounded.

3. Power  supply  must  enter  back  box  through  the  knockouts.

See  also  TOP marking  on  the  back  box  for  proper 
orientation.

4. Verify the power supply voltage coming to heater matches

the ratings as shown on the heater nameplate.

CAuTIon: 

ENERGIzING HEATER AT A VOLTAGE GREATER

THAN THE VOLTAGE PRINTED ON THE NAMEPLATE WILL
DAMAGE THE HEATER AND VOID THE WARRANTY AND
COULD CAUSE A FIRE.

5.

CAuTIon

-  High  temperature,  risk  of  fire,  keep  electrical

cords, drapery, furnishings, and other combustibles at least
3  feet  (0.9  m)  from  front  of  heater.  Do  not  install  heater
behind doors, below towel racks, in the ceiling, or in an area
where it is subject to being blocked by furniture, curtains or
storage materials. Hot air from the heater may damage cer-
tain fabrics and plastics.

6. To  reduce  the  risk  of  fire,  do  not  store  or  use  gasoline  or

other  flammable  vapors  and  liquids  in  the  vicinity  of  the
heater.

7.

This heater is to be mounted only using back box and may
be installed with the back box recessed or surface mounted
as described within this manual. 

8. The following minimum clearances must be maintained:

Bottom of heater to floor - 8” (203 mm) - optimum height
is 18” to 24”.

Sides  of  heater  to  adjacent  wall  -  8”  (203  mm)  - 
optimum minimum 12” (305 mm).

Top of heater to ceiling - 36” (915 mm).

9. Do not operate the heater without the grille installed.

10. Do  not  use  this  heater  for  dry  out  as  the  paint,  plaster, 

sawdust and drywall sanding dust will permanently damage
the heater and must be kept out of the heater.

Figure 1: Locating Recessed Back Box in New Construction

GROUND
SCREW

BACK BOX

CABLE
CLAMP

8” MIN.

(203mm)

NAIL OR SCREW
(2 EACH SIDE)

8” MIN.

(203mm)

POWER SUPPLY CABLE 

Figure 2: Locating Recessed Back Box in Existing Construction

BACK BOX

8” MIN.

(203mm)

8” MIN.

(203mm)

18-1/2” MIN.

(470mm)

14-1/2” MIN.

(362mm)

GROUND SCREW

CABLE CLAMP

NAIL OR SCREW
(2 EACH SIDE)

POWER SUPPLY CABLE 

Содержание K151FC

Страница 1: ...s heater only as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons 11 This heater is intended for comfort heating applications and not intended for use in special environments Do not use in damp or wet locations such as marine or greenhouse or in areas where corrosive or chemical agents are present 12 When installing see I...

Страница 2: ...ng 2 All wiring procedures and connections must be in accordance with the National and Local Codes having jurisdiction and the heater must be grounded 3 Power supply must enter back box through the knockouts See also TOP marking on the back box for proper orientation 4 Verify the power supply voltage coming to heater matches the ratings as shown on the heater nameplate CAuTIon ENERGIzING HEATER AT...

Страница 3: ...Then remove the knockout from the top of the box and proceed to step c b Remove the knockout on the top side of the frame c Feed the power supply cable through the frame allowing 6 152mm of lead to remain inside the frame d Secure the power supply cable to the back box using cable clamps connector or other suitable strain relief allowing 6 152mm of lead to remain inside the inner housing e Ground ...

Страница 4: ...y a qualified repair person MAInTenAnCe InSTruCTIonS It is important to keep this heater clean Your heater will give you years of service and comfort with only minimum care To assure efficient operation follow the simple instructions below user Cleaning Instructions 1 After the heater has cooled a vacuum cleaner with brush attachment may be used to remove dust and lint from exterior surfaces of th...

Страница 5: ... WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS AGREEMENT MARLEY ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR CONSEqUENTIAL DAMAGES ARISING WITH RESPECT TO THE PRODUCT WHETHER BASED UPON NEGLIGENCE TORT S...

Страница 6: ...6 notes notas notes ...

Страница 7: ...s o chispas No lo utilice en áreas en las que se utilice o almacene gasolina pintura o líquidos inflamables 10 Utilice este calefactor únicamente de la manera descrita en este manual Cualquier otra forma de uso no recomendada por el fabricante puede ser causa de incendio choque eléc trico o daños personales 11 Este calefactor está destinado a aplicaciones de calefacción ambiental y no es para util...

Страница 8: ... mismo desde el tablero principal de servicio 2 Todos los procedimientos de cableado y conexiones deben hac erse de conformidad con los códigos nacionales y locales que ten gan jurisdicción y el calefactor debe estar conectado a tierra 3 La alimentación eléctrica debe ingresar a la caja posterior a través de los prepunzonados Verifique también la marca ARRIBA TOP de la caja posterior para asegurar...

Страница 9: ...úe con el paso c b Extraiga el prepunzonado de la cara superior del bastidor c Pase el cable de alimentación eléctrica a través del bastidor dejando 152 mm 6 de cable dentro del bastidor d Asegure el cable de alimentación eléctrica a la caja posterior use abrazaderas o conector para cables u otro alivio de tensiones adecuado dejando 152 mm 6 de cable dentro del alojamiento interior e Conecte a tie...

Страница 10: ...i por alguna razón el control de seguridad contra sobretemperatura no funciona como está previsto Si se activa este fusible térmico el calefactor no volverá a funcionar y debe ser reparado por un técnico de servicio califi cado InSTruCCIoneS de MAnTenIMIenTo Es importante mantener limpio este calefactor Su calefactor le brindará muchos años de servicio y confort con sólo un mínimo de cuidado Para ...

Страница 11: ...PRESA O IMPLÍCITA Y POR LA PRESENTE SE DECLINA Y EXCLUYE DE ESTE ACUERDO TODA GARANTÍA IMPLÍCITA DE COMERCIABILIDAD Y ADECUACIÓN A UN PROPÓSITO PARTICULAR qUE EXCEDA LAS GARANTÍAS EXPRESAS ANTEDICHAS MARLEY ENGINEERED PRODUCTS NO SE HARÁ RESPONSABLE POR DAÑOS CONSIGUIENTES qUE SE PRODUzCAN CON RESPECTO AL PRODUCTO EN BASE YA SEA A NEGLIGENCIA AGRAVIO RESPONSABILIDAD ESTRICTA O CONTRATO Algunos est...

Страница 12: ...12 notes notas notes ...

Страница 13: ... des étincelles électriques Ne l utilisez pas dans des zones où de l essence ou des liquides inflammables sont util isés ou entreposés 10 N utilisez ce radiateur que comme c est décrit dans ce manuel Toute autre utilisation non recommandée par le constructeur peut causer un départ d incendie une commotion électrique ou des blessures corporelles 11 Ce radiateur est prévu pour des applications de ch...

Страница 14: ...tre en conformité avec les normes nationales et locales applicables et le radia teur doit être relié à la terre 3 L alimentation secteur doit entrer dans le boîtier arrière au travers des pastilles à enfoncer Voir également le marquage de HAUT sur le boîtier arrière pour la bonne orientation 4 Vérifiez que la tension du secteur arrivant au radiateur correspond bien aux valeurs spécifiées sur sa pl...

Страница 15: ... alimentation secteur au travers de ce trou Puis enfoncez la pastille en haut du boîtier et passez à l étape C b Enfoncez la pastille sur le côté du dessus de l en cadrement c Passez le câble d alimentation secteur au travers de l en cadrement en laissant 6 152 mm de fils à l intérieur du boîtier arrière d Fixez ce câble sur le boîtier arrière en utilisant passe fils connecteur ou autre attache co...

Страница 16: ...onS d enTreTIen Il est important de garder propre le radiateur Votre radiateur vous fourni ra des années de bon service et de confort avec juste un minimum de soins Pour assurer son fonctionnement efficace suivez les instructions simples ci dessous Instructions de nettoyage par l utilisateur 1 Une fois que le radiateur est froid vous pouvez utiliser un aspirateur avec son accessoire brosse pour él...

Страница 17: ...eux doit être retourné au centre de réparation agréé par Marley le plus près ou au centre de réparation de la société Marley Engineered Products Il sera ensuite gratuitement réparé ou remplacé à notre discrétion et les frais de port de retour seront pris en charge par Marley Il est entendu que cette réparation ou ce remplacement constitue le seul et unique recours disponible auprès de la société M...

Отзывы: