background image

– 8 –

LUBRICANTS FOR MARLEY GEAREDUCERS

To insure maximum performance and service life, The Marley
Cooling Tower Company recommends Marley factory ap-
proved oils be used in all Marley spiral bevel Geareducers. You
can purchase Marley approved oils through your local Marley
sales office in one-gallon and five-gallon containers.

If you must use any oil other than Marley factory approved oil,
the lubricant must not contain any additives (such as deter-

gents or EP additives) which are adversely affected by mois-
ture and could reduce the service life of the Geareducer. The
responsibility for use of oils other than Marley approved
lubricants rests with the customer/user and the lubricant
supplier.

Seasonal temperature changes may require one viscosity of
oil for summer operation and another for winter operation. Use
the following table as a guide.

The Mobil synthetic lubricants listed below may be used where extended service intervals are desired (up to five years).

Severe Duty/High Temperature

Above 110

°

F

Mobil SHC 630

Winter or Summer

32

°

F to 110

°

F

Mobil SHC 629

Table II.  Air Temperature at Geareducer

Turbine-type mineral oils conforming to the viscosity requirements outlined in Table I may be used. These lubricants will provide
service life of up to six months.

Table I.  Air Temperature at Geareducer

Winter

Below 32

°

F

SAE 20

Viscosity S.U.S.

At 100

°

F 230-310

(Heat Exchangers Only)

Winter or Summer

32

°

F to 110

°

F

SAE 30

Viscosity S.U.S.

At 100

°

F 450-610

Summer

Above 110

°

F

SAE 40

Viscosity S.U.S.

At 100

°

F 750-1000

5800 Foxridge Drive — P.O. Box 2912 — Mission, Kansas 66202

913  362-1818

Содержание Geareducer 20 Series

Страница 1: ...1 JANUARY 1992 RM 20H Field Repair Instructions Series 20 20T 20 1 STANDARD AND TYPE CC EXTENDED FAN SHAFT GEAREDUCER M A N U A L FIELD REPAIR SERIES 20 20T 20 1 GEAREDUCERS...

Страница 2: ...2 Series 20 20T 20 1 Cross Section Figure 1 Gear Match Numbers and Setting Data...

Страница 3: ...hickness of this shim pack Item 5 1 is important in the backlash setting of the gears The shim pack should either be saved or carefully measured with a micrometer The gear hub may be removed by using...

Страница 4: ...4 Figure 2 Exploded Cross Section Series 20 20T 20 1 Geareducer...

Страница 5: ...5 Figure 3 Gear Backlash Measurement Figure 4 Bottom Cap Early models were supplied with a gasket between the case and bottom cap In place of gasket use Permatex Form A Gasket No 2 as shown...

Страница 6: ...Use a short piece of pipe with outside diameter 010 to 020 in Iess than the retainer outside diameter Do not apply hammer blows or uneven pressure directly to seal sur face Be careful not to tip retai...

Страница 7: ...im pack Item 5 1 equal to this depth and replace the disc Tighten the inside bolt circle before tightening the outside bolt circle Use 85 to 90 foot pounds torque Recheckthebacklashtomakesureitiswithi...

Страница 8: ...asonal temperature changes may require one viscosity of oil for summer operation and another for winter operation Use the following table as a guide The Mobil synthetic lubricants listed below may be...

Отзывы: