21
wiring diagrams
T1-L1
T2
T3
T4
T8
T5-L2
Capacitor Start Single Phase Motors,
Reversible, Double Voltage
Without Thermal Overload (Integral hp)
High Voltage
1. Connect T1 and L1 and insulate.
2. Connect T2, T3 and T8 and insulate.
3. Connect T4, T5 and L2 and insulate.
Low Voltage
1. Connect T2, T3, T8 and L1 and insulate.
2. Connect T2, T4, T5 and L2 and insulate.
With Thermal Overload (Fractional hp)
High Voltage
1. Insulate P2.
2. Connect T2, T3 and L8 and insulate.
3. Connect T4, T5 and L2 and insulate.
4. Connect P1 and L1 and insulate.
P1-L1
T2
T3
T4
T8
T5-L2
T2
➠
T1-L1
T2
T3
T4
T8
T5-L2
T2
T2
T3
T4
T8
T5-L2
P1-L1