21
2. Nine Wire Dual Voltage Motors—Leads are numbered 1, 2, , 4, 5, 6,
7, 8 and 9 or T1, T2, T, T4, T5, T6, T7, T8 and T9.
Wiring Diagrams
Low Voltage
1. Connect P1 and L1 and insulate.
2. Connect P2, T, and T8 and insulate.
. Connect T2, T4, T5 and L2 and insulate.
General
Colors may be substituted for numbers as follows:
T1—Blue
T5—Black
T2—White
T6—Red
T—Orange
P1—No Color Assigned
T4—Yellow
P2—Brown
To reverse rotation, interchange leads T5 and T8.
Three Phase Motors
There are two basic ways of wiring a three phase motor, Wye and Delta.
The following show the terminal connections that could be used in Marley
motors. Numbers could be stamped on insulation or cloth, plastic or metal
bands around each lead.
1. Three Wire Single Voltage Motors—Leads are not always numbered.
They could be numbered 1,2, or T1, T2 and T.
T2
T3
T1
WYE
T2
T3
T1
DELTA