Marley 542 Скачать руководство пользователя страница 1

Ceiling Mounted 

Fan Forced Heater

SERIES 500

Read Carefully -  These  instructions  are  written  to  help  you
prevent  difficulties  that  might  arise  during  installation  of
heaters. Studying the instructions first may save you consid-
erable  time  and  money  later.  Observe  the  following  proce-
dures and cut your installation time to a minimum.

1.

To prevent electrical shock, disconnect all power coming
to heater at main service panel before wiring or servicing.

2.

All wiring must be in accordance with the National and 
Local Electrical Codes and the heater must be grounded
as a precaution against possible electric shock.

3.

Verify the power supply voltage coming to heater match-
es the ratings printed on the heater nameplate before 
energizing. 

4.

Do not install the heater closer than 12” (305mm) to any 
wall  for models 548, 542, 547 and 24” (610mm) to any 
wall for models 558, 552 and 557.

5.

Do not insert or allow foreign objects to enter any ventila-

tion or exhaust opening as this may cause an electric 
shock, fire, or damage to the heater.

6.

To prevent a possible fire, do not block air intakes or 
exhaust in any manner. Keep combustible materials, such
as crates, drapes, etc., away from heater. 

7.

Aheater has hot and arcing (sparking) parts inside. Do 
not use it in areas where gasoline, paint, or flammable   
liquids are stored.

8.  This heater is not approved for use in corrosive atmos-

pheres such as marine, green house, or chemical storage
areas.

9.

The heater enclosure must be securely mounted to ceil-
ing or framing capable of supporting the heater (45 lbs /
20.4 kg).  Failure to do so could allow heater to fall.

10. Do not operate heater without outlet grilles installed.  

When installing grilles with louver guides, make sure 
guides drop into position so they cannot slide out during 
use.

WARNING

SAVE THESE  INSTRUCTIONS

!

Dear Owner,

Congratulations!  Thank you for purchasing this new heater manufactured by a division of Marley
Engineered Products.  You have made a wise investment selecting the highest quality product in the heat-
ing industry.  Please carefully read the installation and maintenance directions shown in this manual.
You should enjoy years of efficient heating comfort with this product from Marley Engineered Products...
the industry’s leader in design, manufacturing, quality and service.

... The Employees of
Marley Engineered Products

Installation & Maintenance Instructions

1

Recessed Mount

Surface Mount

Содержание 542

Страница 1: ...n any manner Keep combustible materials such as crates drapes etc away from heater 7 A heater has hot and arcing sparking parts inside Do not use it in areas where gasoline paint or flammable liquids are stored 8 This heater is not approved for use in corrosive atmos pheres such as marine green house or chemical storage areas 9 The heater enclosure must be securely mounted to ceil ing or framing c...

Страница 2: ...th the control IMPORTANT Field Conversion for Lower Wattage Rating Figure 12 To convert the heater to a lower wattage rating completely remove one 1 red jumper wire from one heating element for 25 wattage reduction Completely remove two 2 red jumper wires for a 50 wattage reduction Discard the jumper s Be sure the remaining wires are securely connected Conversion for 3Ø Installation Heater is fact...

Страница 3: ...le to three phase voltage refer to Electrical Wiring Figure 12 page 5 8 Position the heater section over the studs in the recess mounting box Figure 3 NOTE The end of the heater section with the terminal block must be positioned at the end of the recess mounting box where the supply wiring enters 9 Push the heater section on to the studs and securely tighten four nuts supplied on the studs to secu...

Страница 4: ...mounting box Figure 8 NOTE The end of the heater section with the terminal block must be positioned at the end of the recess mounting box where the supply wiring enters 13 Push the heater section onto the studs and securely tighten four nuts supplied on the studs to secure the heater section to the recess mounting box Figure 8 14 Connect the ground wire to the green ground screw on the recess moun...

Страница 5: ...g air to flow from the center of the heater 2 After the operational check set the thermostat to obtain the desired comfort level NOTE Heater contains a fan delay on shut down The fan energizes immediately when the thermostat turns on the elements Fan will operate for a short time after the heating ele ments are turned off approx 1min TO WIRE 3Ø REFER TO STANDARD WIRING DIAGRAM COMPLETELY REMOVE BL...

Страница 6: ...g both available from Marley Engineered Products When requesting return authorization include all catalog numbers shown on the products HOW TO ORDER REPAIR PARTS In order to obtain any needed repair or replacement parts warranty service or technical information please contact Marley Engineered Products Service Center toll free by calling 1 800 642 HEAT When ordering repair parts always give the in...

Отзывы: