Rutland 504 Windcharger Installation & Operation
Doc No: SM-150 Issue C 17.03.14 14 Marlec Eng Co Ltd
Batteries
Leisure/Deep Cycle batteries are specifically designed
for good performance in terms of charge/discharge
cycles. Batteries are an important part of the
renewable energy battery charging system and should
be sized according to the load requirements and
provide at least 3 days reserve capacity. This will
reduce cycling, prolong the life of the battery and
ensure system reliability during periods of low wind.
x
Permanent connections should always be made to the
battery terminals. Never use crocodile clips or similar
devices. Battery terminals should be well greased with
petroleum jelly or similar.
x
We strongly recommend that one of the charge
regulators available from Marlec is fitted to prevent
batteries becoming overcharged in strong winds and
during low energy consumption periods. A regulator is
essential where gel and sealed batteries are used.
x
Batteries may be linked as shown in the Fig 13. It is
essential to observe polarity as follows:
Red is + Positive Black is - Negative
Batteries in parallel to increase
ampere hours (Fig.13).
Note :
Batteries must not be joined
in series as this will increase the
voltage rating
12v
60Ah
12v
60Ah
Total = 12v
120Ah
1440W
h
Fig 14
Cable Size
Cable
Run (m)
(mm²) SWG
AWG
0-20
2.5
15
13
21-30
4
13
11
31-45
6
11
9
46-80
10
9
7
Cable Specification
The cable used for connection of the Wind charger to
the batteries should be in accordance with Fig 11. The
use of a smaller cable than recommended will reduce
the performance of the charging system.
Cable and connectors are available from your dealer or
the manufacturer.