2.3 Setting the Mode of
Operation or Digital/Delta
Address
Step 1:
Detach the housing (middle section)
(=> Page 55).
The mode of operation or the
Digital/Delta address is set with the
10 coding switches on the digital
electronic circuit.
Caution! Do not confuse the
10 coding switches for the mode
of operation and for the address
on the lower digital circuit board
with the 8 coding switches on the
upper sound effects circuit board!
2.3.1 Setting the Mode of
Operation
Step 2:
The analog mode of operation is set
with switch 10 (designated “0”) of the
10 coding switches.
Switch 10 (0) at off: AC current
Switch 10 (0) at on: DC current
The mode of operation for Märklin
Digital or Delta is automatically reco-
gnized by the electronic circuit.
Important:
Switch 9 must always be kept at
the “off” setting.
2.3.2 Setting Digital/Delta
Address
Step 3:
The Digital/Delta address is set with
switches 1 through 8 of the 10
coding switches.
Example: “17” as the desired address
Switch 6, 7:
on position
Switch 1, 2, 3, 4, 5, 8:
off position
I
mportant
:
The digital addresses 24, 60, 72,
and 78 correspond to the four Delta
addresses.