43
CV
Explanation
Values
Default
Notes
64
PoM
Brake squealing threshold
0 - 255
60945=105
60946=55
60947=55
The higher the value the sooner the
squealing begins, the lower the value the
later the squealing begins. If the value is
too low, no squealing is activated..
66
PoM
Forward trim
0 - 255
128
The CV value divided by 128 gives the fac-
tor with the speed level is multiplied when
the locomotive is running forward.
67
PoM
-
94
PoM
Speed table speed level 1 (Vmin) to
speed table speed level 28 (Vmax)
0 - 255
95
PoM
Reverse trim
0 - 255
128
The CV value divided by 128 gives the fac-
tor with the speed level is multiplied when
the locomotive is running in reverse.
112
PoM
113
PoM
114
PoM
Physical output (mapping): front light mode
Physical output (mapping): front light dimmer
Physical output (mapping): front light period
0 - 16
0 - 255
0 - 255
1
255
20
See table*
bis
135
PoM
Physical output (mapping): rear light,
Aux 1 to Aux 6 (each one in the 3rd block)
See table*
137
PoM
Switching range
0 - 128
128
128 = 50% of speed level, 64 = 25% of
speed level
CV Table for DCC
* An extensive table for function mapping can be found on the Internet at:
www.maerklin.de/de/produkte/tools_downloads/technische_infos.html
PoM must be supported by the locomotive
controller / central controller.